COMSPHERE 392xPlus Modems
4-2
November 1996
3920-A2-GN31-30
•
Factory is a read-only (unchangeable) configuration area containing six sets of predefined
configuration options labeled Sync Leased, Async Leased, TMp (Trellis Multipoint),
Async Dial, Sync Dial, and UNIX Dial. If Sync Leased or Async Leased is selected, you
must choose either Answer or Originate mode. If TMp is selected, you must choose either
Control or Trib (Tributary) mode. These sets contain the most commonly used
configurations options for modems installed into these hardware environments. These
predefined configuration options are intended to give you a head start and only require a
minimum of changes to the default settings. Factory default settings are listed in
Appendix F.
Figure 4-1 graphically displays the interaction between the edit area and configuration areas as
viewed from the perspective of the DCP.
CONTENTS OF Active (Saved) ARE AUTOMATICALLY COPIED
TO Active (Operating) WHEN A SAVE IS COMMANDED VIA THE
DCP, ON A RESET, OR ON POWER-UP.
Active (Operating)
Active (Saved)
Customer1
Customer2
Factory
EDIT AREA
ALLOWS YOU TO VIEW AND
EDIT CONFIGURATION OPTIONS
ANY CHANGES MADE TO
CONFIGURATION OPTIONS
ARE SAVED TO Active (Saved),
Customer1, OR Customer2
Load Edit
Area From
S
Sync Leased*
(Answer/Originate)
S
Async Leased*
(Answer/Originate)
S
TMp (Control/Trib)
S
Async Dial
S
Sync Dial*
S
UNIX Dial
Save
To
*Multiport mode
Figure 4-1. DCP Configuration Process