COMSPHERE 3825Plus Modem
5-2
November 1996
3825-A2-GB30-20
NOTE
If a connection is not established
between a local COMSPHERE
modem and a remote 3825
Plus
modem, the LCD displays Remote
Mode Fail – No Circuit. Press any
key to return to the Top Level
menu, and dial again.
If the remote modem accepts the password and the
entry is successful, the Top-Level menu of the remote
modem appears on the local modem’s LCD. An appears
in the upper right-hand corner indicating that what is
displayed on your LCD is actually the Top-Level menu of
the remote 3825Plus modem.
F1
Online : 28.8
Control ExitRem
F2
F3
The Top-Level menu of the remote 3825Plus modem is
similar to the local COMSPHERE modem with the
following exceptions:
•
Change Directory is the only function available
under the Call Setup branch.
•
Self-Test and Local Analog Loop do not appear
under the Test branch when using the secondary
channel. When using the primary channel, the Test
branch does not appear.
•
In the Control branch, Make Busy is not available.
•
The Security Branch is not available.
•
Exit Remote replaces Remote on the local modem’s
LCD.
To return to local modem operation, select ExitRem.
Any changes made to configuration options while using
the Remote branch are not saved until you exit the
Remote branch.
The following conditions can cause Remote Access to
fail:
•
The local modem is not able to communicate with
the remote modem because of a poor dial network
or leased-line connection, or the remote modem is
not a 3825Plus modem. If this is the case, the status
message No Response appears on the LCD.
•
If a connection is established but the remote
modem’s Access from Remote configuration option
is disabled, then the status message Access
Disabled appears on the LCD.
•
If a connection is established but the wrong
password is stored, the status message Password
Invalid appears on the LCD.