background image

F2X14-E IP Modem

User Manual

Document Version

Confidential

V2.0.0

Product Name

F2X14-E

Total: 34

F2X14-E IP Modem User Manual

The user manual is suitable for the following model

Model

Product Type

F2114-E

GPRS IP MODEM

F2814-E

FDD LTE IP MODEM

Xiamen Four-Faith Smart PowerTechnology Co.,Ltd.

Hotline

400-8838 -199

Tel

+86-592-6300320

Fax

+86-592-5912735

Web

https://en.four-faith.net/

Add

11th Floor, A-06 Area, No.370, Chengyi

Street, Jimei, Xiamen, Fujian, China

Summary of Contents for F214-E Series

Page 1: ... The user manual is suitable for the following model Model Product Type F2114 E GPRS IP MODEM F2814 E FDD LTE IP MODEM Xiamen Four Faith Smart PowerTechnology Co Ltd Hotline 400 8838 199 Tel 86 592 6300320 Fax 86 592 5912735 Web https en four faith net Add 11th Floor A 06 Area No 370 Chengyi Street Jimei Xiamen Fujian China ...

Page 2: ...Page 2 of 31 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net Files Revised Record Date Version Remark Author 2016 4 29 V1 0 0 Initial version HFQ Faine 2016 7 27 V1 0 1 Add pin definition CM CHEN 2017 9 23 V2 0 0 Add pin level description of LED state output Faine 2020 4 16 V2 0 0 Contents translation and layout Zoe ...

Page 3: ...chnology Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Fo...

Page 4: ... manual Xiamen Four Faith Smart Power Technology Co Ltd Add Floor 11 Area A06 No 370 chengyi street Jimei Xiamen China Page 4 of 31 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net Product appearance ...

Page 5: ...tallation and Cable Connection 11 2 4 Power introduction 12 2 5 Indicator 12 2 6 PIN Definition 13 2 7 PIN level description of LED status 15 Chapter 3 Configuration 17 3 1 Interface specification 17 3 2 Configuration options 20 3 2 1 Local serial port Settings 20 3 2 2 Local serial port 2 Settings 20 3 2 3 DTU Working mode Setting 20 3 2 4 GPRS dial parameter setting 21 3 2 5 Support platform rel...

Page 6: ... parameter setting 23 3 2 13 User defined UDP frame format 23 3 3 Read Write configuration 24 3 4 Modification configuration 25 Chapter 4 Use Description 26 4 1 Working mode description 26 4 1 1 DC mode 26 4 2 Connection mode description 26 4 2 1 Long connection mode 26 4 2 2 Short connection mode 27 4 3 Check system and connection status 27 4 4 Remote upgarde 28 4 5 Local serial upgrade 29 Charpt...

Page 7: ... has been widely used on M2M fields such as intelligent substation intelligent distribution network smart electricity meters intelligent interactive terminal intelligent scheduling intelligent home appliances intelligent electricity building power grids for smart cities intelligent power generation system smart grids Such as new energy storage systems and so on Application system topology Network ...

Page 8: ...fixing conveniently and quickly High performance Support TCP server and support 4 TCP client connection optional Support protocol conversion between ModBus and RTU TCP optional Support dual data center backup transmission and multiple data center synchronous transmission 5 data centers Support multi data centers and it can support 1 5 data centers at the same time Support protocol conversion betwe...

Page 9: ...Mbps HSPA Download speed 21Mpbs Upload speed 5 76 Mbps HSDPA Download speed 7 2Mbps HSUPA Upload speed 5 76Mbps UMTS 384Kbps RX sensitivity 23dBm Standard and Band 97dBm Interface type Item Content SDI Num of ports 2 Port 1 TTL Port 2 TTL Serial port type 2 20PIN 1 27 pitch female header Stop bits 1 2 Parity none even odd Baud rate 300 115200bps Antenna IPEX connector 50 ohm SIM UIM Standard clams...

Page 10: ...dd Floor 11 Area A06 No 370 chengyi street Jimei Xiamen China Page 10 of 31 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net Other parameters Item Content Working temperature 40 75ºC 40 167 Storage temperature 40 85ºC 40 185 relative humidity 95 unfreezing ...

Page 11: ...asement List For transport safely proper packaging IP MODEM is usually required Please take good care of the packing materials when you unpack so that they can be used for future transportation IP MODEM include below components IP MODEM host 1 pcs According to customer s order User manual 1 pcs Rod antenna 1 pcs IPEX connector Note The antenna may have been assembled to the host during packaging p...

Page 12: ... device that indicate the direction of installation make sure the SIM card s metal interface is facing down so that it is in full contact with the socket and be fastened 2 4 Power introduction Usually IP MODEM was embedded to the mainboard of the device In order to adapt to the complex application environment and improve the stability of the system IP MODEM adopts advanced power technology It can ...

Page 13: ...nd centers are connected Note 1 ON means LED always bright hold for at least 3 seconds 2 OFF means LED always off hold for at least 3 seconds 3 Flash slowly means flash frequency is about 1 S 4 Flash quickly means flash frequency is about 1 200ms 5 X means any status 2 6 PIN Definition Details of each pin definition of IP MODEM are shown in the following table PIN NO Name Description Remark 1 2 3 ...

Page 14: ...ge 0V 3 3V 25 TXD2 Serial port 2 Send data 3 3V TTL level VOH 2 5 VOL 0 5 26 Online Output indicate the module is online Low level Default High level After GPRS is online VOH 2 5 VOL 0 5 27 LED_MODULE Output indicate module status See table in section 2 7 28 RXD2 Serial port 2 Receive data 3 3V TTL level VIH 2 0 VIL 0 8 29 LED_SIM Output indicate SIM card status See table in section 2 7 30 LED_STA...

Page 15: ...300320 Fax 0592 5912735 https en four faith net IP MODEM 2 20 PIN female header sequence is showing as below Bottom Bottom view of IP MODEM 2 7 PIN level description of LED status Except 4 LEDs of IP MODEM network running status and SIM indication are extracted through pin customers can choose them according to their own needs The output levels for each state are shown in the following table ...

Page 16: ...e slowly X The module is initializing 2 X High low level alternate slowly High low level alternate quickly Dialing 3 LED_SIM LED_Status Output High low level alternatively X System dialing is successful but centers are not connected 4 LED_SIM LED_Status Output high low level synchronously X System dialing is successful and centers are connected Note 1 High level output hold for at least 3 seconds ...

Page 17: ...32 to TTL serial port line connect F2X14 E to computer power on after chosing right serial configuration parameters the serial port can be used for system parameter configuration Note The configuration page can be entered with baudrates of 115200 and 8N1 in the first 3 seconds after booting Open configuration tool F2x14d_Soft15031718 exe showing as below Open the configuration tool after chosing r...

Page 18: ...cally identifying the available serial ports of the current PC these serial ports are listed in the select serial port Please be patient when you click this item because it is slow to automatically identify the currently available serial port please select the serial port that was connected to F2X14 E and chose right parameter which be used Check the auto option configuration software can automati...

Page 19: ...version The system version will display in the status bar above the configuration software if it query successfully 6 Click the tree menu on the left of the screen the information window in the middle of the interface will display the configuration information under the tree menu especially click the level 1 tree menu All the configuration information is displayed in the information window where y...

Page 20: ... port stop bits 1 1 5 2 Option Serial port parity bits None odd Even Local serial port scan interval 100 ms 10 Default Packet response timeout seconds 5 Default Local serial port frame size bytes 1024 Default set optionally Range 10 1024 Note 1 Local serial port is usually used for configuration Local serial port 2 is used to transfer data and support configuration function 2 For data ports change...

Page 21: ...st one activation mode 3 2 4 GPRS dial parameter setting GPRS CDMA dial number A dialing number for accessing a mobile network Access point name APN This is required when accessing a mobile network GPRS CDMA dial user name A user name is required when dialing into a mobile network GPRS CDMA dial password A password is required for dial up access to a mobile network PPP heartbeat interval Seconds T...

Page 22: ... resolution server address DNS IP2 0 0 0 0 3 2 7 Multi IP data center When chose multi centers mode fill in the IP address port number and connection mode of extension 1 enterprise gateway extension 4 enterprise gateway leave blank for single center mode Note In the case of multi center setting please fill in the IP and port of each center correctly In the case of non multi center setting please s...

Page 23: ...tion of gateway platform Factory defined can not be modified Gateway platform address IP address and port number of gateway platform Gateway platform heartbeat interval seconds Heartbeat interval of gateway platform range 30 600 3 2 11 Administrator login Settings Administrator login account Administrator Name Settings for administrator Administrator login password Administrator password Settings ...

Page 24: ...t the same time as well as other frames The purpose is to enable the enterprise gateway to know about the state of the bottom device in real time 3 3 Read Write configuration Click Read when the power on hardware detection is normal and you log in as the administrator the configuration parameters in the device can be read to the configuration software interface display at this point you can view t...

Page 25: ...ou need to modify the configuration you can read the original configuration modify the corresponding configuration parameters and then write configuration to modify the required parameters Or you can export and save the configuration information on the first write to the configuration When you need to modify the configuration enter the save file then modify the corresponding configuration paramete...

Page 26: ...tom device and the data center can be realized Function As a communication bridge between the bottom equipment and the data center Such as RTU PLC etc the data sent by the bottom device to the serial port is encapsulated into network packets and sent to the data center and he data from the data center can also be sent to the bottom device through the serial port 4 1 Working mode description 4 1 1 ...

Page 27: ... control when to connect and when to disconnect For example set Timing off line interval 55 Timing activate interval 600 Phone activation open Local data activation close after networking it will automatically log off and enter the waiting activation state after 5 minutes without data transmission in the serial port in this state you can use calling to make it works or it will connect to network a...

Page 28: ...sh frequency is about 1 S If the center doesn t open it was defaulted to be normal state 4 4 Remote upgarde If you need to upgrade the program remotely please contact us to get the version number of the upgraded software and the address of the server where the upgraded software is located Command RMTUPGRADE aa b cc ip port ver Function upgrade Parameter meaning aa The properties of the upgrade The...

Page 29: ...uograde Parameter None For example 123456 STPUPGRADE 4 5 Local serial upgrade 1 Open DTUDowanLoad exe multiplex download tool what our company provide Chose upgrade program file use RS232 serial port line to connect F2X14 E to PC Do not power F2X14 E showing as below 2 Power F2X14 E now it will start upgrading showing as below When the upgrade is complete the red box showing as below will be displ...

Page 30: ...itions before your test 1 A computer with Internet access run the test software F2X14D_DC exe on this computer in order to listen for a certain TCP UDP port for communication 2 Use RS232 serial port line to connect the device to the computer 3 A SIM card that has already open data service 5 1 DC Test 5 1 1 DCUDP mode Open F2X14D_DC exe showing as below Working mode must be configurated to DCUDP Co...

Page 31: ...e button to stop listening on the port If you want to open it again click Control Start service button to start listening on the port 3 When the device connect to data center successfully local device number login time corresponding IP information will list in the window showing as below 4 You can test communication with data center now Data that data center received will show up in infomation win...

Page 32: ...hese data will send to data center Showing as below Data can be sent to the specified port through the center software Select the device number you want to send from the list local device number will be displayed in the corresponding window at the bottom and input data in the bottom of the right window click Send button data will be send out by software showing as below Data sent by the center to ...

Page 33: ...mei Xiamen China Page 33 of 34 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net 5 1 2 DCTCP mode test Open test tool F2X14D_DC exe click TCP to enter TCP mode F2X14D_DC exe will work on TCP mode at this moment you can start test if you config the device to DCTCO mode Test steps is similar to UDP mode ...

Page 34: ...o the remote server Solution 1 Check parameter of F2X14 E is right or not 2 Check SIMcard is insert correctly or not make sure the SIM card is not stopped Can be tested by dialing the card number 3 If the remote data server is within the LAN check that firewall port mapping Settings are correct or not Question 4 Unable to transmit data to field control equipment when connect to server data manager...