DTE Connection

Use the following procedure to connect the RS-232D

cable from the modem to the DTE:

1. Make sure the modem’s rear panel power switch is

Off.

2. Connect the DB-25-P (male) connector on the

cable to the DB-25-S (female) connector labeled
DTE 1 (Figure 2) on the modem’s rear panel. Use
a small screwdriver to tighten the cable to the
modem.

3. Connect the DB-25-P connector on the cable to

the DB-25-S connector on the DTE. Use a small
screwdriver to tighten the cable to the DTE.

Connecting 3820

Plus Modems

with Supplied Cables

Figure 2 shows how 3820Plus modems are connected

to certain TELCO jack types using the supplied cables.
For other TELCO connections, refer to Appendix D of the
COMSPHERE 3800Plus Modems User’s Guide.

3820

Plus Dial-Line Connection

Use the following procedure to connect the 3820Plus

modem to the dial network interface:

1. Insert the 6-position, 4-conductor modular plug

into the jack labeled DIAL (Figure 2).

2. Insert the other end of the modular cord into the

dial network interface (“demarc”).

3820

Plus 2-Wire Leased-Line Network

Connection

Use the following procedure to connect a 3820Plus

modem to the leased-line network interface:

1. Insert the 8-position, 8-conductor modular plug

into the jack labeled LEASED (Figure 2).

2. Insert the other end of the modular cord into the

leased-line network interface (“demarc”).

AC Power Supply Connection

WARNING

Power supplies from other
modems may fit into the DIN
jack, but connecting the
wrong power supply can
cause damage to the modem
or the power supply.

Use the following procedure to connect the modem to

an ac power outlet:

1. Make sure the modem’s power switch is in the Off

position.

2. Insert the power transformer’s 8-pin DIN male

connector into the modem’s rear panel power
receptacle (Figure 2).

3. Connect the power supply to a grounded ac power

outlet.

Summary of Contents for COMSPHERE 3820Plus

Page 1: ...You have accessed an older version of a Paradyne product document Paradyne is no longer a subsidiary of AT T Any reference to AT T Paradyne is amended to read Paradyne Corporation ...

Page 2: ...own in the COMSPHERE 3800Plus Modems User s Guide 3980 A2 GB30 10 The Model 3982 A1 401 modem has an 8 pin modular jack for leased line connection and a 6 pin modular jack for dial line connection The model shown in the User s Guide has a single jack for leased line or dial line connection Use these instructions to install your modem and keep them with your User s Guide Figure 1 3820Plus Modem Mod...

Page 3: ...20Plus modem has the following switches and connectors see Figure 2 An ON Off power switch An 8 pin DIN type power receptacle for the table top power supply An 8 pin modular keyed jack for 2 wire leased lines A 6 pin modular keyed jack for dial PSTN lines A 4 pin modular jack for network management system NMS connection A 25 pin DB 25 S receptacle for DTE interface 8 POSITION PLUG FOR LEASED LINE ...

Page 4: ...Plus modem to the dial network interface 1 Insert the 6 position 4 conductor modular plug into the jack labeled DIAL Figure 2 2 Insert the other end of the modular cord into the dial network interface demarc 3820Plus 2 Wire Leased Line Network Connection Use the following procedure to connect a 3820Plus modem to the leased line network interface 1 Insert the 8 position 8 conductor modular plug int...

Page 5: ...e modem s rear panel power switch to the ON position The modem begins a power up self test This test takes several seconds to perform and verifies the operation of most hardware components within the modem If successful the LCD displays Power On Selftst Passed and continues to the Top Level menu screen F1 Power On Selftst Passed F2 F3 If a failure occurs during the self test the LCD may display Po...

Reviews: