5
Table 1
(4 of 8)
New Features and Changes
Feature or
Configuration
Option
Notes
S46:
Bad Lines Auto
Originate
3810: pp. 4-40, 5-24
The Auto Dial Backup Control option (S46) has been
expanded and is now designated Bad Lines Auto
Originate. On modems with a shared or integral
Diagnostic Control Panel (DCP), if the Sync Leased
factory preset template is selected, the following options
are available under the Leased Line configuration option
BdLn Auto Orig:
Disable:
The modem will not perform a Bad Lines
Auto Originate.
Enable:
The modem will originate a call after
30 seconds of continuous bad-line
conditions.
FastBackup: The modem will originate a call after
20 seconds of continuous bad-line
conditions.
2_min:
The modem will originate a call after
2 minutes of continuous bad-line conditions.
5_min:
The modem will originate a call after
5 minutes of continuous bad-line conditions.
10_min:
The modem will originate a call after
10 minutes of continuous bad-line
conditions.
The Bad Lines Auto Originate value also can be set with
the S46=
n command:
S46=0
Disable
S46=1
30 Seconds
S46=2
20 Seconds
S46=3
60 Seconds
S46=4
90 Seconds
S46=5
120 Seconds
. .
. .
. .
. .
S46=21
600 Seconds
Note that the S46=2 command (FastBackup) has an
effect that is out of sequence with the other values. This
ensures downward compatibility by preserving the
meaning of S46=1 (Enable) as 30 Seconds.