COMSPHERE 3800Plus Modems
13-16
October 1998
3980-A2-GB30-40
Table 13-1
(14 of 15)
3800
Plus AT Commands
AT Command
Front Panel Branch
Description
%R
Async DTE Rate
Sets the DTE rate for Asynchronous mode. This configuration option has
no effect in Sync or Async Direct modes, where the DTE rate always
equals the VF rate.
%R
n must be the last command in a command string.
The %R
n command does not disable autobauding. If a command is
received from the DTE at a new rate, the modem will autobaud to that rate,
replacing the current %R value. If a factory preset is selected with an
AT&F
n command, the autobauding rate is not changed.
Rates above 19,200 bps are not defined in RS232E, but can function
correctly in many cases. For higher rates, take the following precautions:
•
Use as short a DTE cable as possible. A special low-capacitance cable
may be required.
•
For an IBM-compatible PC, ensure that the serial port uses a buffered
UART such as the 16550.
If you experience overruns, it may be that your DTE cannot handle higher
DTE rates. Try a lower value.
%R300
0–300 bps
%R1200
1200 bps
%R2400
2400 bps
%R4800
4800 bps
%R7200
7200 bps
%R9600
9600 bps
%R12000
12,000 bps
%R14400
14,400 bps
%R19200
19,200 bps
%R28800
28,800 bps
%R38400
38,400 bps
%R57600
57,600 bps
%R76800
76,800 bps
%R115200
115,200 bps
Configure\Edit\
DTE Interface
#DM
n
SDC Delay Minimization
Minimizes the delay introduced by SDC by allowing the modem to
transmit a DTE frame to its DTE in a discontinuous way.
#DM0
No delay minimization. The modem does not begin
transmitting a frame to its DTE until the entire frame has been
received.
#DM1
Delay minimization. The modem begins to transmit data from
a DTE frame to its DTE even if the end of the DTE frame has
not yet been received by the modem.
Configure\Edit\
V42/MNP/Buffer
#Q
n
Sync Flow Ctrl
Controls the type of synchronous data flow control while using data
compression.
#Q0
No flow control.
#Q1
Flow control using transmit clock (circuit 114).
#Q2
Flow control using CTS (circuit 106).
Configure\Edit\
V42/MNP/Buffer
Summary of Contents for COMSPHERE 3800PLUS
Page 1: ...COMSPHERE 3800PLUS MODEMS USER S GUIDE Document No 3980 A2 GB30 41 February 2002 ...
Page 10: ...COMSPHERE 3800Plus Modems iv October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 52: ...COMSPHERE 3800Plus Modems 6 6 October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 60: ...COMSPHERE 3800Plus Modems 7 8 October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 174: ...COMSPHERE 3800Plus Modems B 4 October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 182: ...COMSPHERE 3800Plus Modems D 4 October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 196: ...COMSPHERE 3800Plus Modems G 6 October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 198: ...COMSPHERE 3800Plus Modems H 2 October 1998 3980 A2 GB30 40 This page intentionally left blank ...
Page 217: ...00282600 ...