COMSPHERE 6800 Network Management System Command
Quick Reference Guide (6800-A2-GB15-10)

The modifications in this guide are described as follows.

The DDD Service Restoration Menu was updated to include the following additional menu items:

5) chspid – Change SPID

6) dsspid – Display SPID

The DDD Device Control menu was updated to include the following additional menu item:

5) rs – Reset Device

The DSU Device Control menu was updated to include the following additional menu item:

4) rs – Reset Device

The DDD Circuit Tests menu was updated to include the following additional menu item:

3) ct – Call Test

Summary of Contents for COMSPHERE 3800PLUS

Page 1: ...the 3821Plus modems 3821Plus 3825Plus Release 4 0 modems and the two 3610 3611 DBMs ISDN and V 34 plus information on the Synchronous Data Compression feature in support of the 3800Plus R3 0 release...

Page 2: ...rms Table A 1 in Appendix A is changed to reflect the new device number 3821 In the COMSPHERE 6800 Series Network Management System Command Quick Reference Guide 6800 A2 GB15 10 two new menu items are...

Page 3: ...uration Change Notification ccn Display Options dso Display SPID dsspid Display Telephone Number dstn Download Device Firmware dndf Identity id Reset Device rs The Call Statistics application function...

Page 4: ...esults can be specified The input screen contains the following fields Device This field specifies the device to be tested Test Type This field indicates the kind of dial test to be performed Currentl...

Page 5: ...7 6800 A2 GK66 20 October 1996 Change Address cha This command is supported for 3821Plus modems...

Page 6: ...ntains the new values of 7 2 16 8 19 2 21 6 24 0 26 4 28 8 and 64 The Single rate field with the values yes and no only displays if the DBM is a 12K or 14 4K DBM The DBM Diagnostic Configuration Set s...

Page 7: ...fill field are DirectMode and Mark_Fill The values for SDC bit encoding field are NRZ and NRZI The MISC Configuration Set screen contains the new field Mixed trib F W with the values of yes and no Th...

Page 8: ...cape char field 1 255 The V42 MNP BUFFER Configuration Set screen contains seven new fields Sync Compression mode SDC negotiation SDC idle fill SDC bit encoding Sync DTE CRC Sync flow control and SDC...

Page 9: ...at B1 This field specifies the SPID number at B1 A valid SPID number consists of the ASCII characters 0 9 with a length of 3 20 If the field is left blank the SPID will be removed SPID number at B2 Th...

Page 10: ...llows Local number 1 For the first local telephone number this field accepts 36 characters with the same character set as the non ISDN DBM single local number Local number 2 For the second local telep...

Page 11: ...ge was added for the Change SPID chspid command when the ccn command is used to display the configuration events In the description of the Configuration Change Notification results screen in the manua...

Page 12: ...Status dhs The Expanded Status field for 3600 Series R3 5 DSUs can now display the following facility alarms facility alarm rate conflict alarm facility alarm cross pair detection alarm facility alarm...

Page 13: ...Display SPID dsspid command supports 3610 3611 DSUs The input form contains the following field Device This field specifies the device s for which the SPID numbers are to display The Display SPID resu...

Page 14: ...process turn off channel polling and increase the timeout interval 2 seconds is recommended by performing the following steps 1 Enter the Edit Alert Monitoring State edams command 2 On the edams scree...

Page 15: ...strapping field for 392x modems A new field is valid Special Functions with the option XLOOP to support the 3610 and 3611 Release 3 3c DSUs The feature SDC Synchronous Data Compression displays in the...

Page 16: ...d allows users to reset the 3600 Series R3 5 DSUs This command can be scheduled and the destination for results can be specified The input screen contains the following field Device s This field speci...

Page 17: ...00 A2 GB20 10 The changes or modifications to the commands in this guide are described as follows Table 2 1 is updated to include two new commands Command Command Abbreviation APL DDD DDS Disruptive U...

Page 18: ...26 10 The changes or modifications to the commands in this guide are described as follows Table 5 2 is updated with two alerts added to the Alert Group apl terminal The Alert Type ela has a textual di...

Page 19: ...was updated to include the following additional menu items 5 chspid Change SPID 6 dsspid Display SPID The DDD Device Control menu was updated to include the following additional menu item 5 rs Reset D...

Page 20: ...35 232 Time Division Multiplexer Circuit Card Central Site Digital Bridge and Sequoia application present V 35 232 MCMP CCA Sequoia Multichannel Multipoint Circuit Card and Sequoia application presen...

Page 21: ...uit Card Central Site Digital Bridge and Sequoia application present 6 p Flex MCMP CCA Sequoia Multichannel Multipoint Circuit Card and Sequoia application present 6 p Flex MCMP CCA CBrdg S Multichann...

Reviews: