DSU Operations
5-43
3610-A2-GB41-70
July 1999
Control Branch
The Control (Ctrl) branch allows you to enable or
disable the DSU’s transmitter, as well as the DBM’s, and
to display/change the status of the general purpose
external DTE leads.* For a DSU operating in TDM or
MCMP mode, the Control branch allows the transmitter to
be enabled or disabled on a per-port basis. It also allows
you to choose which of the six ports is to have its circuit
leads monitored.
When in TDM or MCMP mode, the following
selections appear:
F1
Control Funct:
TxCt l
LEDs
ExtL
F2
F3
When in Bridge mode, the following selections appear:
F1
Control Funct:
LEDs
ExtL
F2
F3
When in Basic mode, the following selections appear:
F1
Control Funct:
TxCt l
ExtL
F2
F3
A DBM can be disabled if it is addressed from the
Remote branch. The Control branch menu has three
selections. Table 5-13 lists the selections on the Control
branch menu.
Table 5-13
Control Branch Menu Options
Menu
Selection
Purpose
TxCtl
Enables or disables the DSU’s
transmitter, or the DBM’s call
setup or answer capability.
LEDs
Selects whether the port or
aggregate data stream is
monitored on the faceplate
LEDs.
1
ExtL
Provides status and control of
two external input leads and two
output leads available for
optional customer assignment.
1
Only applies to TDM or MCMP applications, and
only in Local mode.
Refer to the COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611, Operator’s Guide for
additional information and examples.
* DSU and DBM subbranches are valid for Local mode only; Devic and Ports are displayed for Remote mode. Also, if
General configuration option Ext Leads is set to ExtLd, Chang is not displayed.
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB41 70 Notices...
Page 22: ...COMSPHERE 3600 Series Data Service Units 1 10 July 1999 3610 A2 GB41 70...
Page 52: ...COMSPHERE 3600 Series Data Service Units 3 14 July 1999 3610 A2 GB41 70...
Page 67: ...Principles of Operation 4 15 3610 A2 GB41 70 July 1999 Figure 4 10 FEP Port Sharing...
Page 114: ...COMSPHERE 3600 Series Data Service Units 4 62 July 1999 3610 A2 GB41 70...
Page 161: ...A 1 3610 A2 GB41 70 July 1999 Data Service Unit Menu A...
Page 162: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB41 70...
Page 163: ...Data Service Unit Menu A 3 3610 A2 GB41 70 July 1999...
Page 164: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB41 70...
Page 170: ......
Page 174: ......
Page 196: ...COMSPHERE 3600 Series Data Service Units C 18 July 1999 3610 A2 GB41 70...
Page 230: ...COMSPHERE 3600 Series Data Service Units D 34 July 1999 3610 A2 GB41 70...