Paradyne COMSPHERE 3550 Series Installation Instructions Manual Download Page 8

8

4. Select area (Activ, Remt, Usr1) on the Save to screen.

If Activ is selected, your changes take effect immediately.

If Usr1 is selected, your changes are stored for future use.

If the unit is a control and Remt is selected, the complete configuration (all option sets available to the
unit and their configuration option settings) is sent to the tributary and saved to its Activ area.

Remember that you cannot save to the factory-loaded configurations. Command Complete appears when
the configuration has been saved.

5. Reconnect the DDS interface cable to the DSU (labeled LINE).

6. Reconnect the NMS (labeled CC/DC) and DBM (labeled BACKUP) interface cables to the DSU’s rear

panel, if installed.

7. Perform a Digital Test on each port.

Select the  

  key 

!

 Local 

!

 Test 

!

 DSU 

!

 the  

  key 

!

DT 

!

 Start 

!

 (e.g.) Prt1 

!

 enter Address

!

 RunTim (hh:mm:ss).

Command Complete appears at the conclusion of the test.

8. Press the  

  key, then select Displ to see the results of the Test.

9. Press the  

  key to scroll the results.

Refer to the Digital Test section in Chapter 4 of the user’s guide for the results you should expect.
Refer to Chapter 2 of the user’s guide to verify network and DBM operation.

10. Reconnect the EIA-232-D/V.24 or V.35 interface cable to the DSU. Connect the Port 2 interface cable to

the DSU, then to the DTE.

If

 

the TDM/Flex port is to be connected to a DCE, attach a 15-foot crossover cable (feature number

4951-035F) to the port, and connect it to the appropriate DCE.

If configuring Port 2 for V.35 operation, attach the V.35 Interconnect Cable (feature number 3000-F1-510)
to the port, then to the DTE.

Summary of Contents for COMSPHERE 3550 Series

Page 1: ...data communications equipment DCE a crossover cable is required feature number 3211 178F for a V 35 Crossover Cable or feature number 4951 035F for an EIA 232 Crossover Cable If using V 35 operation a...

Page 2: ...DSU s rear panel labeled POWER 2 Disconnect the DDS interface cable labeled LINE from the DSU 3 Disconnect the DBM and NMS interface cables labeled BACKUP and CC DC respectively if installed 4 Disconn...

Page 3: ...to an upright position 4 Fold the DSU s cover over from the rear of the DSU toward the front Be careful not to pull the LCD and keypad flat cables from their connectors 496 14518 01 CO MS PH ER E 36 1...

Page 4: ...panel Set the DSU on a clean ESD anti static workpad 6 Write the serial number from the existing base onto the new TDM Flex expanded base using indelible ink see Figure 2 Discard the existing base an...

Page 5: ...5 Figure 3 Installing the TDM Flex...

Page 6: ...tion installed During the tests all indicators on the diagnostic control panel DCP light briefly and the LCD displays the message Power up Tests When the Device Tests are complete the LCD momentarily...

Page 7: ...ppears then select MUX 2 Select Setup F2 3 If MUX Funct is not set to Enab select Enab The selected setting appears on the first line of the display 4 Press the key to return to the MUX submenu To con...

Page 8: ...7 Perform a Digital Test on each port Select the key Local Test DSU the key DT Start e g Prt1 enter Address RunTim hh mm ss Command Complete appears at the conclusion of the test 8 Press the key then...