Paradyne COMSPHERE 3550 Series Installation Instructions Manual Download Page 6

6

Reassembling the Unit

Refer to 

Figure

 3

 as you close the unit and to 

Figure 1

 to reconnect cables.

Procedure

1. Align the cover over the expanded base and rear panel. Make sure the four snap tabs are over their

corresponding slots (two in front and two in back).

2. Apply pressure at the four snap tab connecting points, pressing together until all four tabs snap securely

into their slots.

3. Reconnect the power cord to the DSU (labeled POWER), referring back to 

Figure 1

.

4. Plug the table-top ac transformer into the ac outlet.

On power-up, the DSU determines what options (DBM, MUX – TDM/Flex) are installed.

A Device Test is automatically initiated on the DSU and each option installed. During the tests, all
indicators on the diagnostic control panel (DCP) light briefly, and the LCD displays the message
Power-up Tests.

When the Device Tests are complete, the LCD momentarily displays messages indicating that each device
(DSU and MUX, or DBM if installed) has passed the power-up test. This test takes approximately
20 seconds to complete
.

Note that the red Alarm LED lights, indicating that there is no DDS signal.

5. Perform a DSU Device Test from the DCP to ensure that the unit is functioning properly.

Press the  

  key to return to the top-level menu, then select Local 

 Test 

 DSU 

 Devic.

6. If the keypad and/or LCD functions fail, check that the Keypad and LCD flat cables are installed properly.

Perform the Device Test again.

If the Device Test fails again, call your service representative for assistance. Otherwise, continue with this
procedure.

Summary of Contents for COMSPHERE 3550 Series

Page 1: ...data communications equipment DCE a crossover cable is required feature number 3211 178F for a V 35 Crossover Cable or feature number 4951 035F for an EIA 232 Crossover Cable If using V 35 operation a...

Page 2: ...DSU s rear panel labeled POWER 2 Disconnect the DDS interface cable labeled LINE from the DSU 3 Disconnect the DBM and NMS interface cables labeled BACKUP and CC DC respectively if installed 4 Disconn...

Page 3: ...to an upright position 4 Fold the DSU s cover over from the rear of the DSU toward the front Be careful not to pull the LCD and keypad flat cables from their connectors 496 14518 01 CO MS PH ER E 36 1...

Page 4: ...panel Set the DSU on a clean ESD anti static workpad 6 Write the serial number from the existing base onto the new TDM Flex expanded base using indelible ink see Figure 2 Discard the existing base an...

Page 5: ...5 Figure 3 Installing the TDM Flex...

Page 6: ...tion installed During the tests all indicators on the diagnostic control panel DCP light briefly and the LCD displays the message Power up Tests When the Device Tests are complete the LCD momentarily...

Page 7: ...ppears then select MUX 2 Select Setup F2 3 If MUX Funct is not set to Enab select Enab The selected setting appears on the first line of the display 4 Press the key to return to the MUX submenu To con...

Page 8: ...7 Perform a Digital Test on each port Select the key Local Test DSU the key DT Start e g Prt1 enter Address RunTim hh mm ss Command Complete appears at the conclusion of the test 8 Press the key then...