1. Installation
1-6
March 2005
2600-A2-GN20-40
Mounting Configurations
Three basic installation configurations are available:
Rack mount – see
Installing the Brackets for Rack Mounting
on page 1-6 and
Installing the BitStorm 2600 Into a Rack
on page 1-8.
Wall mount – see
Installing the BitStorm 2600 on a Wall
on page 1-10.
Shelf or desktop – see
Installing the BitStorm 2600 on a Shelf or Desktop
on
page 1-12.
Mounting Brackets
Your BitStorm 2600 can be installed in a rack or on the wall using mounting
brackets. Two brackets suitable for a 19-inch (483 mm) rack (marked EIA-19) and
two brackets suitable for a 23-inch (584 mm) Bay Networks or Nortel rack (marked
with Paradyne Part Number 868-6282-0020) are shipped with the unit. Two
brackets suitable for a 21-inch (535 mm) rack (marked ETSI) are available from
Paradyne as a separate feature (see
Appendix B,
Equipment List
).
Rack-mounting brackets may also be used to attach the unit to a wall.
NOTE:
In this guide, the term
rack
refers to any rack, cabinet, frame, or bay suitable
for mounting telecommunications equipment.
Installing the Brackets for Rack Mounting
Procedure
To install the mounting brackets for rack mounting:
1. Locate the black screw nearest the front panel on each side of the unit, as
shown.
2. Remove these two black screws (one from each side) before attempting to
install the mounting brackets.