Setting Up
5-46
9161-A2-GH30-40
April 1999
Assigning OCU-DP Data Ports
Use the OCU-DP Port Assignments screen to view the status of:
H
All DS0 assignments on the Network interface
H
All DS0 assignments on the DSX-1 interface
You can also use this screen to assign OCU-DP data ports to:
H
Network interface time slots
H
DSX-1 interface time slots
NOTES:
You can assign OCU-DP ports to the DSX-1 interface on the 9161 Single
T1 NAM. OCU-DP port assignments on the Dual DSX APM are not
supported.
"
Procedure
1. Follow this menu selection sequence:
Configuration Edit/Display
→
Cross Connect
→
OCU-DP Port Assignment
2. The OCU-DP Port Assignments screen appears. Enter one of the following
into the Assign To field:
If you want to assign to . . .
Then enter . . .
Network interface time slots
Net1 or Net2
DSX-1 interface time slots on the 9161
Single T1 NAM
DSX01-1
3. Move the cursor to the next editable time slot (underlined). Use the spacebar
or type in the desired slot and port. Repeat this step until all desired time
slots are assigned.
4. Select Save to save the assignments, or press ESC to save and return to the
Cross Connect menu.
Summary of Contents for 9261
Page 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 40 April 1999 ...
Page 34: ...Management and Control 2 6 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 54: ...User Interface 4 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 92: ...Setting Up 5 38 9161 A2 GH30 40 April 1999 Example Channel Allocation ...
Page 142: ...Security 6 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 252: ...IP Addressing B 8 9161 A2 GH30 40 April 1999 This page intentionally left blank ...