SP+ Series Programming Guide
37
Zone Options
Use the following section to program zone options for your SP+ Series control panel.
ATZ, Zone Tamper, and Supervision Options
General Zone Options
Table 25: Description of section [705]
Option Description
OFF
ON
Sec
tion
[705]
1
ATZ zone doubling
Disabled
Enabled
2
ATZ wiring options
Series
Parallel
3
Tamper recognition
(see table 26 for details)
4
5
Generate tamper on bypassed zone
No
Yes
6
Supervision options
(see table 26 for details)
7
8
Generate supervision on bypassed zone
No
Yes
= Default
NOTE:
ATZ is only available for the .
Table 26: Description of options 3 & 4 and 6 & 7, in section [705]
Option
Description
3
4
RF Zone/Hardwired Zone Tamper Recognition Options
Keypad/Bus Module Tamper Recognition Options*
OFF
OFF
Disabled
Disabled
OFF
ON
Trouble only
Trouble only
ON
OFF
When disarmed: trouble only; when armed: follow zone’s alarm type
Trouble only
ON
ON
When disarmed: audible alarm; when armed: follow zone’s alarm type
Audible alarm
6
7
RF Zone Supervision Options
Keypad/Bus Module Supervision Options
OFF
OFF
Disabled
Disabled
OFF
ON
Trouble only
Trouble only
ON
OFF
When disarmed: trouble only; when armed: follow zone’s alarm type
Trouble only
ON
ON
When disarmed: audible alarm; when armed: follow zone’s alarm type
Audible alarm
* Tamper recognition of keypad/bus module, only if section
[700]
, option 7, is enabled.
Table 27: Description of section [706]
Option
Description
OFF
ON
Se
c
ti
o
n
[706]
1
Check-in supervision time
24 hours
80 minutes
2
EOL resistors (applies to all hardwired zones – panel, keypad, ZX8/ZX82)
Disabled
Enabled
3
Zone input 1 becomes a two-wire smoke input
Disabled
Enabled
4
ZX8/ZX82 ID A (panel + 1) input 1
Zone input
Tamper input
5
ZX8/ZX82 ID B (panel + 9) input 1
Zone input
Tamper input
6
ZX8/ZX82 ID C (panel + 17) input 1
Zone input
Tamper input
= Default