Enter the dealership service email address 

Enter the customers email address.    Use a comma between addresses (example: 

[email protected] <mailto:[email protected]>, [email protected]

Once all setup information has been setup, go to connections and bind the RS232 connection.    This will 
automatically begin processing the setup information with the alarm panel. 

 

Downloading Zone, Area and User Label information: 

Cinegration has added in the support to download Area, Zone and User label data from the 

Paradox system.    To download, go to actions, and press the corresponding download label that you 
want.    Note: This may take extra time depending on the number of zones or users the panel has.   
Once the download is complete, the dealer will need to double-click on each zone and adjust the zone 
type properties for each 

 

 

Connecting Zones Proxies to the Driver 

The dealer should add sensors for each zone and bind them to the correct input on the panel.   

This step allows programming on the zone level in Control4 programming.    (see image below for an 
example of properly setup zone binding list) 

 

Summary of Contents for PRT3

Page 1: ...all partitions easily from Control4 interfaces MyHome iPad iPhone Android Control4 GUI supported Zone labels and usernames are downloaded into Control4 system from Paradox panel Custom Entry and Exit...

Page 2: ...setup o Number of zone in Paradox panel o Values can be 0 192 Note changing this number will remove all existing connections Number of Partitions default 1 o Required for driver setup o Number of par...

Page 3: ...turn on off when the alarm goes off Note this will last until the alarm is turned off or 4 minutes have expired whichever comes first The delay between on off is 2 seconds Service Email o Automatic e...

Page 4: ...ontrolled Always should be left in the off state Hide from UI screens Shows or Hides the zone in the zones page of the security driver on the GUI Typically all connected zones should be shown and non...

Page 5: ...Setup Paradox via Babyware Programming Right click on the PRT3 module and choose Properties o Select the Options Tab o Enable 016 1 Serial Port on off o Enable 016 4 Turn on Home Automation Protocol o...

Page 6: ...t to download Area Zone and User label data from the Paradox system To download go to actions and press the corresponding download label that you want Note This may take extra time depending on the nu...

Page 7: ...Control4 2 8 2 and higher Control4 systems Warranty Cinegration strives to provide fully working drivers without defects However changes and bugs may be found Because of this any bug maintenance upda...

Reviews: