background image



Partition - EntryDelay 

o  entry delay for partition in seconds

 

Default: 30 (seconds)



Use Locale Words 

Used to set the language parameter for the driver. 



Users in system 

Number of users in the system.    Note: changing this number will remove all existing users 
from the driver.    Dealer will need to select action ‘Download user labels’ to get new labels 
for users. 



User Settings 

Dynamic property built off property ‘Users in system’.    This property allows dealers to 
choose which username they would like to edit 



Edit User 

Used in conjunction with User Settings.    Will display the current username value of user 
selected in User Settings.    Note: user name does not have to match Paradox username. 

 

Alarm_Action: Flash Lights 

o

      Choose which lights will turn on/off when the alarm goes off.    Note: this will last until the         

alarm is turned off or 4 minutes have expired, whichever comes first.    The delay between on/off 
is 2 seconds. 



Service Email 

Automatic emailing of troubles, alarms, device connection state changes to dealer.    Requires 
4Sight service at project and the email agent to be in the project. 



Customer Email 

Automatic emailing of arm, disarm, and alarms to the customer’s email.    Requires 4Sight 
service at project and the email agent to be in the project.

 

Actions Tab (System Design)

 



Download Area Labels 

Used to download the area labels that are stored in the PRT3 module. 



Download Zone Labels 

Used to download the zone labels for each zone that is stored in the PRT3 module 



Download User Labels 

Used to download the user labels that are stored in the PRT3 module 



Request Area Status 

Sends a check area status command to the Paradox.    The driver will process the area status and 

Summary of Contents for PRT3

Page 1: ...all partitions easily from Control4 interfaces MyHome iPad iPhone Android Control4 GUI supported Zone labels and usernames are downloaded into Control4 system from Paradox panel Custom Entry and Exit...

Page 2: ...setup o Number of zone in Paradox panel o Values can be 0 192 Note changing this number will remove all existing connections Number of Partitions default 1 o Required for driver setup o Number of par...

Page 3: ...turn on off when the alarm goes off Note this will last until the alarm is turned off or 4 minutes have expired whichever comes first The delay between on off is 2 seconds Service Email o Automatic e...

Page 4: ...ontrolled Always should be left in the off state Hide from UI screens Shows or Hides the zone in the zones page of the security driver on the GUI Typically all connected zones should be shown and non...

Page 5: ...Setup Paradox via Babyware Programming Right click on the PRT3 module and choose Properties o Select the Options Tab o Enable 016 1 Serial Port on off o Enable 016 4 Turn on Home Automation Protocol o...

Page 6: ...t to download Area Zone and User label data from the Paradox system To download go to actions and press the corresponding download label that you want Note This may take extra time depending on the nu...

Page 7: ...Control4 2 8 2 and higher Control4 systems Warranty Cinegration strives to provide fully working drivers without defects However changes and bugs may be found Because of this any bug maintenance upda...

Reviews: