
PARADOX.COM
PCS265L-EI04 11/2021
GSM Reporting (EBUS Connection)
Reporting Options
SMS Messages for Backup
Additional Programming Options
SMS Language
SMS Programming
Refer to the panel’s respective user manual for more information on
SMS Personal Reporting.
List of SMS Commands
Please note that the default password is
admin
.
EN Certification
The following statements apply for EN 50131 and EN 50136
certification:
• Mode of operation is pass-through
• PCS265LTE must be installed and connected to an EN approved
Grade 3 control panel
• Monitoring of the transmission network interface (Internet
connection): In case of network/interface failure, the device sends
a trouble message to the control panel which then displays it via
connected keypad(s)
• Information Security is achieved by 256-bit encrypted, supervised
communication (AES validation number 986) which prevents
unauthorized reading or modification of messages
• Substitution Security is achieved by Information Security (as stated
above), physical security (Tamper protection) and by a unique
Serial Number from each device. Messages sent to the receiving
station include the S/N in order to identify the substitution and alert
accordingly
Technical Specifications
Safety Note:
This device may operate continuously in temperature of
55°C (
131°F)
for a maximum period of 7 days.
MG/SP
EVO
Details
[805]
[2950]
[1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM
backup (default)
[1] On + [2] Off = GSM primary / landline
backup
[1] On + [2] On = GSM only
[815] to
[817]
[3071] to
[3074]
Telephone numbers
[811] to
[812]
[3061] to
[3068]
Account numbers
Command
Description
P[PASSWORD].SMS[GSM MODEM
TELEPHONE #].[IPRS-7 PASSWORD]
Used to program the
receiver’s SMS parameters
Language
Value
Language
Value
English (default)
000
Bulgarian
016
French
001
Romanian
017
Spanish
002
Slovak
018
Italian
003
Chinese
019
Swedish
004
Serbian
020
Polish
005
Malay
021
Portuguese
006
Slovenian
022
German
007
Lithuanian
023
Turkish
008
Finnish
024
Hungarian
009
Estonian
025
Czech
010
French Canadian
026
Dutch
011
Belgian
027
Croatian
012
Latvian
028
Greek
013
Albanian
029
Hebrew
014
Macedonian
030
Russian
015
Section
SMS Site Name Label
EVO
[2954]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
MG/SP
[780]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Command
Description
P[password].A[IP
address].P[port number]
Used for LTE/4G/3G/2G remote
access
P[password].IP.[call back
phone number]
Used to obtain the IP address and IP
port of the PCS265 LTE and whether
or not the “bandwidth saver” option is
being used
P[password].RESET
Used to power cycle the PCS265
LTE
P[password].VOLOUT.[GSM
output volume]
Used to set the GSM output
volume; values range between 50 to
100
P[password].STATUS.[phone
number]
Used to obtain the signal strength,
signal quality, LTE/4G/3G/2G
connection status, and APN
settings of the current SIM card
P[password].
APN1.NAME.
[Access Point Name]
Used to program the SIM Card 1
APN
P[password].
APN1.USER.
[Access Point Name]
Used to program the SIM card 1 APN
User Name
P[password].
APN1.PSW.
[Access Point Name]
Used to program the SIM card 1 APN
Password
P[password].
APN1.CLEAR]
Used to clear the SIM Card 1 APN
P[password].
VAPN1.[CALL BACK PHONE
NUMBER]
Used to view the SIM Card 2 Access
Point Name information
P[password]. APN2.NAME.
[Access Point Name]
Used to program the SIM Card 2
Access Point Name
P[password].
APN2.USER.
[Access Point Name]
Used to program the SIM Card 2
Access Point User
P[password].
APN2.PSW.
[Access Point Name]
Used to program the SIM Card 2
Access Point Password
P[password].
APN2.CLEAR
Used to clear the SIM Card 2 Access
Point Name
P[password].
VAPN2.[CALL BACK PHONE
NUMBER]
Used to view the SIM Card 2 Access
Point Name information
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/
IP4W1/ IP4W2].[domain name]
Set domain name for LTE/4G/3G/2G
receiver
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/IP4W1/ IP4W2]
.CLEAR
Clear domain name for LTE/4G/3G/
2G receiver
C[user code].[ARM/
OFF].A[area number], [area
number], [area
number]TO[area number]
Arm/Disarm
P[password].---S
Disable SWAN polling
(V4.10.011 and higher)
P[password].+++S
Enable SWAN polling
(V4.10.011 and higher)
Specifications
Description
RF Power
Class 4 (2W) @ 850/1900 MHz
Class 2 (1W) @ 1800/1900 MHz
UMTS 850/1900 @ 0.25W (America)
UMTS 900/2100 @ 0.25W (Europe)
Antenna Bandwidth
5 bands, wideband
Voltage Input
12 VDC nominal
Consumption during
GPRS/GSM transmission
60 mA standby
300 mA maximum
Encryption
128-bit (AES)
SMS Protocol
7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)
SIM Cards
LTE/4G/3G
GSM (2G - n/a for North and South
America)
Humidity
0 - 90% non-condensing
Operating Temperature
-20 - 50 °C (-4 to 122 °F)
Dimensions
20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in.
Certifications
EN 50136-1 EN 50136-2 Grade 3
Class II
EN 50131-10 ATS Category SP5
Certification Body: Applica Test and
Certification
Warranty
The Limited Warranty Statement can be found on the website www.paradox.com/terms.
Patents
Your use of the Paradox product signifies your acceptance of these terms and
conditions. The following US patents may apply 5,886,632 and 6,215,399. Other
Canadian and international patents may apply.
©2021 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications
may change without prior notice.