Paradox PCS265 LTE Installation Manual Download Page 4

PARADOX.COM

PCS265L-EI04 11/2021

GSM Reporting (EBUS Connection)

Reporting Options

SMS Messages for Backup

 

Additional Programming Options

SMS Language

SMS Programming
Refer to the panel’s respective user manual for more information on 
SMS Personal Reporting.

List of SMS Commands

Please note that the default password is 

admin

.

EN Certification

The following statements apply for EN 50131 and EN 50136 

certification:

• Mode of operation is pass-through
• PCS265LTE must be installed and connected to an EN approved 

Grade 3 control panel

• Monitoring of the transmission network interface (Internet 

connection): In case of network/interface failure, the device sends 
a trouble message to the control panel which then displays it via 
connected keypad(s)

• Information Security is achieved by 256-bit encrypted, supervised 

communication (AES validation number 986) which prevents 
unauthorized reading or modification of messages

• Substitution Security is achieved by Information Security (as stated 

above), physical security (Tamper protection) and by a unique 
Serial Number from each device. Messages sent to the receiving 
station include the S/N in order to identify the substitution and alert 
accordingly

Technical Specifications

Safety Note: 

This device may operate continuously in temperature of 

55°C (

131°F)

 for a maximum period of 7 days.

MG/SP

EVO

Details

[805]

[2950]

[1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM 
backup (default)
[1] On + [2] Off = GSM primary / landline 
backup
[1] On + [2] On = GSM only

[815] to
[817]

[3071] to 
[3074]

Telephone numbers

[811] to 
[812]

[3061] to
[3068]

Account numbers

Command

Description

P[PASSWORD].SMS[GSM MODEM 

TELEPHONE #].[IPRS-7 PASSWORD]

Used to program the 

receiver’s SMS parameters

Language

Value

Language

Value

English (default)

000

Bulgarian

016

French

001

Romanian

017

Spanish

002

Slovak

018

Italian

003

Chinese

019

Swedish

004

Serbian

020

Polish

005

Malay

021

Portuguese

006

Slovenian

022

German

007

Lithuanian

023

Turkish

008

Finnish

024

Hungarian

009

Estonian

025

Czech

010

French Canadian

026

Dutch

011

Belgian

027

Croatian

012

Latvian

028

Greek

013

Albanian

029

Hebrew

014

Macedonian

030

Russian

015

Section

SMS Site Name Label

EVO

[2954]

__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__

MG/SP

[780]

__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__

Command

Description

P[password].A[IP 
address].P[port number]

Used for LTE/4G/3G/2G remote 
access

P[password].IP.[call back 
phone number]

Used to obtain the IP address and IP 
port of the PCS265 LTE and whether 
or not the “bandwidth saver” option is 
being used

P[password].RESET

Used to power cycle the PCS265 
LTE

P[password].VOLOUT.[GSM 
output volume]

Used to set the GSM output 
volume; values range between 50 to 
100

P[password].STATUS.[phone
number]

Used to obtain the signal strength, 
signal quality, LTE/4G/3G/2G 
connection status, and APN 
settings of the current SIM card

P[password].
APN1.NAME.
[Access Point Name]

Used to program the SIM Card 1 
APN 

P[password].
APN1.USER.
[Access Point Name]

Used to program the SIM card 1 APN 
User Name

P[password].
APN1.PSW.
[Access Point Name]

Used to program the SIM card 1 APN 
Password

P[password].
APN1.CLEAR]

Used to clear the SIM Card 1 APN

P[password].
VAPN1.[CALL BACK PHONE 
NUMBER]

Used to view the SIM Card 2 Access 
Point Name information

P[password]. APN2.NAME.
[Access Point Name]

Used to program the SIM Card 2 
Access Point Name

P[password].
APN2.USER.
[Access Point Name]

Used to program the SIM Card 2 
Access Point User

P[password].
APN2.PSW.
[Access Point Name]

Used to program the SIM Card 2 
Access Point Password

P[password].
APN2.CLEAR

Used to clear the SIM Card 2 Access 
Point Name

P[password].
VAPN2.[CALL BACK PHONE 
NUMBER]

Used to view the SIM Card 2 Access 
Point Name information

P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/ 
IP3W2/
IP4W1/ IP4W2].[domain name]

Set domain name for LTE/4G/3G/2G 
receiver

P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/ 
IP3W2/IP4W1/ IP4W2]
.CLEAR

Clear domain name for LTE/4G/3G/
2G receiver

C[user code].[ARM/
OFF].A[area number], [area 
number], [area 
number]TO[area number]

Arm/Disarm

P[password].---S

Disable SWAN polling
(V4.10.011 and higher)

P[password].+++S

Enable SWAN polling
(V4.10.011 and higher)

Specifications

Description

RF Power

Class 4 (2W) @ 850/1900 MHz 
Class 2 (1W) @ 1800/1900 MHz 
UMTS 850/1900 @ 0.25W (America)
UMTS 900/2100 @ 0.25W (Europe)

Antenna Bandwidth

5 bands, wideband

Voltage Input

12 VDC nominal

Consumption during 
GPRS/GSM transmission

60 mA standby
300 mA maximum

Encryption

128-bit (AES)

SMS Protocol

7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)

SIM Cards 

LTE/4G/3G 
GSM (2G - n/a for North and South 
America)

Humidity

0 - 90% non-condensing

Operating Temperature

-20 - 50 °C (-4 to 122 °F)

Dimensions

20.8 x 7.5 x 2 cm  / 8.2 x 2.9 x 0.8 in.

Certifications

EN 50136-1 EN 50136-2 Grade 3 
Class II 
EN 50131-10 ATS Category SP5
Certification Body: Applica Test and 
Certification

Warranty

The Limited Warranty Statement can be found on the website www.paradox.com/terms.

Patents

Your  use  of  the  Paradox  product  signifies  your  acceptance  of  these  terms  and

conditions.  The  following  US  patents  may  apply  5,886,632  and  6,215,399.  Other

Canadian and international patents may apply.

©2021  Paradox  Security  Systems  (Bahamas)  Ltd.  All  rights  reserved.  Specifications

may change without prior notice.

Summary of Contents for PCS265 LTE

Page 1: ...the PCS265 LTE s serial out to the serial connector on the panel For LTE 4G 3G 2G reporting connect to the Serial port of the panel For GSM reporting connect to the EBUS port of the panel 1 Mounting hole 2 Antenna connector 3 Wall tamper hole 4 Serial connector 5 RS485 power terminal 6 Upgrade connector 7 Battery terminal 8 Cover tamper switch 3 4 5 6 7 2 1 8 1 GSM EBUS Connector LTE 4G 3G 2G Seri...

Page 2: ...ge If configured for LTE 4G 3G 2G reporting you will need to configure network provider information Refer to the Programming section Note The battery is optional If a battery is used installed do not allow the battery to deplete and ensure that the battery is replaced when low The battery function is to support power shut down and not to be used as backup as defined in EN50131 6 LED Functionality ...

Page 3: ...rovider MG SP EVO Feature Details 918 919 2976 to 2983 Account Partition Registration MG SP Sections represent account partition 1 and 2 EVO Sections represent account partition 1 to 8 806 2975 7 Off 8 Off landline only 7 Off 8 On LTE 4G 3G 2G primary landline backup default 7 On 8 Off landline only 7 On 8 On landline and LTE 4G 3G 2G in parallel Receiver Settings MG SP Receiver IP address IP port...

Page 4: ...bers Command Description P PASSWORD SMS GSM MODEM TELEPHONE IPRS 7 PASSWORD Used to program the receiver s SMS parameters Language Value Language Value English default 000 Bulgarian 016 French 001 Romanian 017 Spanish 002 Slovak 018 Italian 003 Chinese 019 Swedish 004 Serbian 020 Polish 005 Malay 021 Portuguese 006 Slovenian 022 German 007 Lithuanian 023 Turkish 008 Finnish 024 Hungarian 009 Eston...

Page 5: ...gram the SIM card 1 APN Password P password APN1 CLEAR Used to clear the SIM Card 1 APN P password VAPN1 CALL BACK PHONE NUMBER Used to view the SIM Card 2 Access Point Name information P password APN2 NAME Access Point Name Used to program the SIM Card 2 Access Point Name P password APN2 USER Access Point Name Used to program the SIM Card 2 Access Point User P password APN2 PSW Access Point Name ...

Page 6: ...temperature of 55 C 131 F for a maximum period of 7 days Specifications Description RF Power Class 4 2W 850 1900 MHz Class 2 1W 1800 1900 MHz UMTS 850 1900 0 25W America UMTS 900 2100 0 25W Europe Antenna Bandwidth 5 bands wideband Voltage Input 12 VDC nominal Consumption during GPRS GSM transmission 60 mA standby 300 mA maximum Encryption 128 bit AES SMS Protocol 7 bit GSM 3GPP TS 23 038 GSM03 38...