Press 852 

Disarmed report delay (default is 5min) 

 

 

 

Set it to 001 for 1min 

 

Press 810  

Program the communicator format for Contact ID 

 

 

 

Press 44 

 

Press 811  

Programming of the dialler account number on partition 1 

 

 

 

Press 1234 

 

Press 812  

Programming of the dialler account number on partition 2 

 

 

 

Press 1234 

 

Press 815 

Programming of the dialler telephone number 1 

 

 

 

Press 1234 

 

Programming zone arming and disarming: 

(Note that Zone 4 and 5 has been used as an example) 

AWAY arming 

Connect relay 1 to zone 5 with the resistor in series on NC and COM 

Enter Section 005 for zone 5 

 

 

 

Press 26 for the zone type as Momentary Key switch   

 

 

 

 

Press 1 for the partition assignment 

 

 

 

None of the zone options should be selected, and press ENTER 

Enter Section 745 for Exit delay on Partition 1 

 

 

 

Press 000 so that the panel can instantly arm when key switch is activated 

STAY Arming 

Connect relay 2 to zone 4 with the resistor in series on NC and COM 

Enter Section 004 for zone 4 

 

 

 

Press 26 for the zone type as Momentary Key switch   

 

 

 

 

Press 1 for the partition assignment 

 

 

 

No. 6 of the zone options should be selected, and press ENTER 

Enter Section 745 for Exit delay on Partition 1 

 

 

 

Press 000 so that the panel can instantly arm when key switch is activated 

Press Clear to exit programming 

 

 

 