Typical PGM (Programmable Output) Programming
Note: For other PGM operations, use
Espload software by programming the desired PGM function and
pressing F8 to see the keypad programming codes and address. If other programming options are
needed, fax your requests to Paradox Technical Support at 514-491-2313.
Special Timing Functions
3 Digit Decimal Value Programming
Decimal programming is used to program addresses 044 to 061. Values entered must contain 3 digits.
Decimal value programming:
1) Press [
ENTER
] + installer code. ([
ENTER
] key will flash.)
2) Enter 3 digit address (044 to 061).
3) Enter 3 digit DECIMAL value.
4) To erase, press [
CLEAR
]. To save, press [
ENTER
].
5) Repeat from step 2 onward for next address. To exit programming mode press [
CLEAR
].
“No movement”
If a time is programmed at address 055, and a report code is entered at address 517 (SECTION 65), the panel
will send a report to the central, when there is no movement in the protected area for a designated time period.
"Late to close"
If the system is not armed by a specified time (addresses 044, 045) the code programmed at address
516 (SECTION 65) will be transmitted.
Auto arming
The panel can be programmed to automatically arm itself every day in two ways: at the specified time pro-
grammed at addresses 044, 045 and/or once the "no movement" delay has elapsed (address 055). To
program "auto arming", go to address 086 and enable key [5] (auto arm on time), and/or key [6] (auto
arm on "no movement"). All zones must be closed in order for the system to auto arm. If panel fails to
auto arm, only the “late to close" (address 516 (SECTION 65)) or the "no movement” (address 517 (SEC-
TION 65)) report will be transmitted. The "auto arm" report is programmed at address 300 (SECTION 11).
FUNCTION
DESCRIPTION
PGM 1
PGM 2
Add. 039
Add. 040
Add. 042
Add. 039
Add. 041
Add. 043
1
ST
digit
2
ND
digit
*
Ground start Pulse
Provides 3 sec. pulse before
[5]
[5]/[2]
[2
ND
]/[8]
[5]
[5]/[2]
[2
ND
]/[8]
(Timed N.O.)
communication attempt.
Push key [1] and [2]
Provides output when keys [1] and
[1]
[5]/[8]
[2
ND
]/[6]
[1]
[5]/[8]
[2
ND
]/[6]
(Regular N.O.)
[2] are pressed simultaneously.
System armed
Output removed when system
[9]
[2]/[11]
[2
ND
]/[8]
[9]
[2]/[11]
[2
ND
]/[8]
(Regular N.C.)
armed.
Strobe output
Provides latching output on
[2
ND
]
[2]/[12]
[2
ND
]/[2]
[2
ND
]
[2]/[12]
[2
ND
]/[2]
(Regular N.O.)
alarm, until disarmed.
Fail to communicate
Provides output upon fail to
[5]
[2]/[6]
[2
ND
]/[4]
[5]
[2]/[6]
[2
ND
]/[4]
(Timed N.O.)
communicate for 2 minutes.
2nd telephone line relay Provides output after one failed
[2
ND
]
[7]/[10]
[2
ND
]/[
MEM
]
[2
ND
]
[7]/[10]
[2
ND
]/[
MEM
]
(Regular N.O.)
communication attempt.
Kiss off
Provides 3 sec. output after signal
[5]
[7]/[
BYP
] [2
ND
]/[8]
[5]
[7]/[
BYP
] [2
ND
]/[8]
(Timed N.O.)
received at monitoring station.
*
Not permitted on UL listed systems.
15
IM738-738EX