16
The virtual input can be closed by either receiving a virtual input close command, after a timer
elapses or either. This option determines how the virtual input will close.
U
= default setting
If the virtual input is set to follow its Virtual Input Timer, the entered value represents the amount of time that the virtual input will remain
open. To program the Virtual Input Timer, enter a 3-digit value from
000
to
255
. Depending on the Virtual Input Base Time (see “Virtual Input
Base Time Selection” on page 16), the Virtual Input Timer will either be in seconds or minutes.
If option
[5]
is OFF, the value programmed for the Virtual Input Timer will be in seconds. If option
[5]
is ON, the Virtual Input Timer will be in
minutes. The following table lists the base time sections and their respective virtual inputs.
U
= default setting
Section [700] - Options [3] and [4]
Virtual Input Close Option
Section
Virtual Input
[3] OFF / [4] OFF
[3] ON / [4] OFF
[3] OFF / [4] ON
[700]
1
U
close command
N
virtual input timer
N
close command or virtual input timer
[710]
2
U
close command
N
virtual input timer
N
close command or virtual input timer
[720]
3
U
close command
N
virtual input timer
N
close command or virtual input timer
[730]
4
U
close command
N
virtual input timer
N
close command or virtual input timer
[740]
5
U
close command
N
virtual input timer
N
close command or virtual input timer
[750]
6
U
close command
N
virtual input timer
N
close command or virtual input timer
[760]
7
U
close command
N
virtual input timer
N
close command or virtual input timer
[770]
8
U
close command
N
virtual input timer
N
close command or virtual input timer
[780]
9
U
close command
N
virtual input timer
N
close command or virtual input timer
[790]
10
U
close command
N
virtual input timer
N
close command or virtual input timer
[800]
11
U
close command
N
virtual input timer
N
close command or virtual input timer
[810]
12
U
close command
N
virtual input timer
N
close command or virtual input timer
[820]
13
U
close command
N
virtual input timer
N
close command or virtual input timer
[830]
14
U
close command
N
virtual input timer
N
close command or virtual input timer
[840]
15
U
close command
N
virtual input timer
N
close command or virtual input timer
[850]
16
U
close command
N
virtual input timer
N
close command or virtual input timer
Section [701]
Virtual Input Timers
Section
Virtual Input
Timer Data
Section
Virtual Input
Timer Data
[701]
1
__/__/__ (000 to 255) x Base time
[781]
9
__/__/__ (000 to 255) x Base time
[711]
2
__/__/__ (000 to 255) x Base time
[791]
10
__/__/__ (000 to 255) x Base time
[721]
3
__/__/__ (000 to 255) x Base time
[801]
11
__/__/__ (000 to 255) x Base time
[731]
4
__/__/__ (000 to 255) x Base time
[811]
12
__/__/__ (000 to 255) x Base time
[741]
5
__/__/__ (000 to 255) x Base time
[821]
13
__/__/__ (000 to 255) x Base time
[751]
6
__/__/__ (000 to 255) x Base time
[831]
14
__/__/__ (000 to 255) x Base time
[761]
7
__/__/__ (000 to 255) x Base time
[841]
15
__/__/__ (000 to 255) x Base time
[771]
8
__/__/__ (000 to 255) x Base time
[851]
16
__/__/__ (000 to 255) x Base time
Section [700] - Option [5]
Virtual Input Base Time Selection
Section
Virtual
Input
[5] OFF
[5] ON
Section
Virtual
Input
[5] OFF
[5] ON
[700]
1
U
seconds
N
minutes
[780]
9
U
seconds
N
minutes
[710]
2
U
seconds
N
minutes
[790]
10
U
seconds
N
minutes
[720]
3
U
seconds
N
minutes
[800]
11
U
seconds
N
minutes