background image

English

Beam Patterns

The DG85 series features the following beam patterns:

Installation

After selecting the detector’s location, drill or punch out holes for the wiring and 
mounting screws as shown in Figure 1.
Avoid placing the detector within proximity of sources of interference such as direct 
sunlight, reflective surfaces and movng cars. 

The DG85 can also be mounted using the Paradox Swivel Mount Bracket (469). 
The swivel mount may allow for easier mounting. If using the swivel mount, it is 
recommended that you seal the space where the swivel mount is connected to 
the back cover with some silicon or with a rubber gasket to ensure that moisture 
does not enter the detector.

After you have installed the detector, ensure that the adjustable height markings on the 
upper right of the PCB’s cover inside the unit match the installation height (see Figure 
2). Any PCB adjustments should be followed by a walk-test to verify detector 
coverage.

 

Do not touch the sensor surface as this could result in a detector malfunction. 
If necessary, clean the sensor surface using a soft cloth with pure alcohol.

Ensure that the unit’s front and back cover are tightly joined together without 
any spacing (around the rim of the unit) before tightening the screw, otherwise 
the weatherproof casing may be compromised and moisture may enter the 
unit.

Operational Modes

The DG85 can function in two different operational modes: combus mode or relay 
mode. This option can only be configured using DIP switch 1.

Relay Mode: (DIP switch 1 = OFF)

When set to Relay Mode, the DG85 functions as would any standard motion 
detector by communicating its alarm and tamper signals via relays. The 

GRN

 

and 

YEL

 terminals are not used in relay mode. 

In Relay Mode, the detector’s settings can only be modified using the DIP 
switches and trimpot (see figure 2).

Combus Mode: (DIP switch 1 = ON)

When set to combus mode, the DG85 communicates alarm signals, tamper 
signals, data and detector settings via the panel’s 4-wire combus. 
The detector’s relay output always remains active even when set to combus 
mode and can be used to activate other devices.
In combus mode, the motion detector can be modified using the DIP switches 
and trimpot or by entering module programming mode.
In combus mode, the DG85 will respect the most recent modification whether it 
is made through the DIP switches and trimpot or through section programming. 
As a result, current DIP switch  and trimpot positions may not represent actual 
settings. All settings are stored in the DG85 even after it has been powered 
down.

Figure / Figura 1

Installation / Instalación

Figure / Figura 2

PCB Connection and Setup / Conexión y Configuración de la PCI / Connexion et 

configuration de la carte de circuits imprimés

Technical Specifications

Protection Level:

I P45

Sensor type:

Dual Element Infrared X 2

RFI / EMI rejection:

10V/m

Sensor geometry:

Rectangular

Voltage input:

9 to 16Vdc

Current consumption: 30mA Maximum
Anti-tamper switch:

150mA/28Vdc, N.C

Lens:

2nd generation 
Fresnel lens, 
LODIFF®, segments

Alarm output:

Form A relay 
100mA28Vdc, N.C. or 
optional form C relay 5A/
28Vdc, N.C./N.O.

Detection speed:

0.2m/s to 3.5m/s (0.6ft/s to 11.5ft/s) Ingress 

Operating temperature:-35°C to +50°C (-31°F to +122°F) 

© 2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. 
One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 
5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. 
Canadian and international patents may also apply. LODIFF® lens: patent #4,787,722 (U.S.). 
Digigard is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, 
the United States and/or other countries. 
LODIFF® is a registered trademark of Fresnel Technologies Inc.
Warranty: For complete warranty information on this product please refer to the Limited Warranty Statement 
found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance 
of all warranty terms and conditions.

Figure / Figura 3

DG85W Pet Array Beam Pattern / Modelo Inmune a Mascotas Estandar DG85W

 

Diagramme de lentilles Couloir pour animaux DG85W 

Figure / Figura 4

DG85L1 Horizontal Curtain Beam Pattern / Modelo Pasaje de Mascotas DG85L1 / 

Diagramme de lentilles Rideau horizontal

 

DG85L1 

Figure / Figura 5

DG85L2 Vertical Curtain Beam Pattern/ Modelo Cortina Vertical DG85L2 / 

Diagramme de lentilles Rideau vertical DG85L2 

Detector Settings

Walk-testing

At 20°C (68°F), at the highest sensitivity setting and in Single Edge Processing mode, 
you should not be able to cross more than one complete zone (consisting of 2 beams, 
left and right sensor detecting elements) in the coverage area with any kind of 
movement; slow/fast walking or running. 
At the lowest sensitivity setting, the amount of movement required to generate an 
alarm is doubled. The approximate width of a full beam at 11m (35ft) from the detector 
is 1.8m (6ft). To walk-test, move across the detection path, not toward the detector.

Detector

Beam Pattern

DG85W

Pet Array beam pattern (see figure 3)

DG85L1

Horizontal Curtain beam pattern (see figure 4)

DG85L2

Vertical Curtain beam pattern (see figure 5)

' *    6 ( 5 , ( 6

Printed in China - 10/2007    paradox.com     DG85-TI06

 

Instructions

Instrucciones

Outdoor Digital Dual-Optic High-

Performance PIR V1.3 

C

C

A

A

A

A

B

B

B

B

E

D

A

-Corner mount
-Montaje en esquina
-Montage en coin

B

  -Flat surface mount

-Montaje superficie plana
-Support pivotant

C

 -Swivel mount bracket

-Soporte de montaje giratorio
-Support pivotant

D

-Wire entry
-Entrada de cableado
-Entrée de fils

E

-Insert foam protection into wire entry
-Insertar la espuma de protección en entrada 
 de cableado
-Insérer de la mousse protectrice à l’entrée }
 des fils

E

-Align height with tab
-Alinear altura con  
 lengüeta
-Aligner la hauteur 
 avec la languette

F

-Detect LED
-LED de detección
-DEL de détection

G

-Trimpot
-Potenciómetro
-Potentiomètre

H

-Electrical connectors
-Conectores eléctricos
-Bornes de 
 raccordement

I

-DIP switch
-Interruptor DIP
-Commutateur DIP

E

F

G

H

I

2,1m 

(7ft)

A

B

C

D

A

-Anti-tamper switch
-Interrupt. 
 antisabotaje
-Interrupteur de 
 sécurité

B

-To Combus 
  Combus mode only)
-Al Combus (modo 
 DGP solamente)
-Au Combus mode 
 DGP seulement)

C

-Power input 
 (+12Vdc)
-Alimentación 
 (+12Vcc)
-alimentation
 (+12 Vc.c.)

D

-Alarm relay
-Relé de alarma
-Relais d’alarme

Co

ver

age

In

st

al

la

tio

n

Hei

ght

Pe

Immu

ni

ty

DG85W

90°

11m x 11m
(35ft x 35ft)

2.1m
(7ft)

40kg
(90lbs)

DG85L1
(Horizontal)

85°

11m x 11m
(35ft x 35ft)

1.1m
(3.6ft)

Multi/large
pet

DG85L2
(Vertical)

5.64°

13m (43ft)
x 2 beams

2.1m
(7ft)

N/A

Ang

le

P

IW

R

7239,(:

6,'(9,(:

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

7239,(:

6,'(9,(:

P

IW

P

IW

P

IW

P

IW

P

IW

7239,(:

6,'(9,(:

P

IW

P

IW

Step

Section / 

DIP 

Details

1

Operational 

Mode

DIP 

Switch 1

DIP switch 1 ON 

=Combus mode (go to step 2)

DIP switch 1 OFF  =Relay mode 

U

 (go to step 3)

2

Enter detector programming mode. 
Press and hold 

[0]

 + 

[

INSTALLER

 

CODE

]

 +

 [4003]

 (EVO) or 

[953]

 (DGP-848) + SN (located on PCB cover).

3

Signal 

Processing 

Mode

Single edge processing should be used in normal 
environments with minimal sources of interference. Dual 
Edge Processing provides better false alarm rejection if the 
detector is placed near sources of interference that can 
adversely affect it.

[001]

or

DIP 

Switch 2 

[1] OFF

=Dual edge

[1]

 ON 

=Single edge 

U

                 or
DIP switch 2 OFF 

=Dual edge 

DIP switch 2 ON 

=Single edge 

U

 

4

LED 

Settings

LED flash = Movement without alarm (see step 5)
LED on 5 sec. = Movement with alarm

[001]

or

DIP 

Switch 3

[2] OFF

=LED disabled

[2] 

ON =LED 

enabled 

U

                 or
DIP switch 3 OFF 

=LED disabled

DIP switch 3 ON 

=LED enabled 

U

5

Movement 

Signal 

Indication

When enabled and a signal is detected that matches the 
characteristics of a movement signal, but does not reach 
the required energy levels for an alarm, the LED flashes 
once, indicating the signal was kept in memory.
Note: The LED must be enabled. (see step 4)

[001]

[3] OFF  =Movement signal disabled

[3] 

ON 

=Movement signal enabled 

U

Note: In relay mode, this feature is enabled if 
         DIP switch 3 = ON.

6

Tamper 

Recognition

When enabled and the anti-tamper switch is open (cover 
removed), the detector sends a tamper message to the 
control panel via the combus.

[001]

[5] 

OFF =Tamper 

recognition 

disabled 

U

[5] ON 

=Tamper recognition enabled

7

Sensitivity

The DG85 features adjustable sensitivity. Adjust from 0 
(lowest sensitivity) to 10 (highest sensitivity).

Depending on the sensitivity setting, an alarm 
condition can be generated between 0.25 sec. 
(highest) and 2 sec. (lowest) after the actual 
movement.

Viewing Sensitivity Settings
Remove the cover to view how many times the LED 
flashes, then adjust the setting accordingly. The LED 
flashes a consecutive amount of times to show the setting. 
Thus if the sensitivity is set to 6, the LED flashes 6 times.

[002]

or

Trimpot

000 =Lowest sensitivity

010 

=

Highest sensitivity 

U

 

Turn clockwise 

=Increase sensitivity

Turn counterclockwise 

=Decrease sensitivity

U

= default settings