English
Beam Patterns
The DG85 series features the following beam patterns:
Installation
After selecting the detector’s location, drill or punch out holes for the wiring and
mounting screws as shown in Figure 1.
Avoid placing the detector within proximity of sources of interference such as direct
sunlight, reflective surfaces and movng cars.
The DG85 can also be mounted using the Paradox Swivel Mount Bracket (469).
The swivel mount may allow for easier mounting. If using the swivel mount, it is
recommended that you seal the space where the swivel mount is connected to
the back cover with some silicon or with a rubber gasket to ensure that moisture
does not enter the detector.
After you have installed the detector, ensure that the adjustable height markings on the
upper right of the PCB’s cover inside the unit match the installation height (see Figure
2). Any PCB adjustments should be followed by a walk-test to verify detector
coverage.
Do not touch the sensor surface as this could result in a detector malfunction.
If necessary, clean the sensor surface using a soft cloth with pure alcohol.
Ensure that the unit’s front and back cover are tightly joined together without
any spacing (around the rim of the unit) before tightening the screw, otherwise
the weatherproof casing may be compromised and moisture may enter the
unit.
Operational Modes
The DG85 can function in two different operational modes: combus mode or relay
mode. This option can only be configured using DIP switch 1.
Relay Mode: (DIP switch 1 = OFF)
When set to Relay Mode, the DG85 functions as would any standard motion
detector by communicating its alarm and tamper signals via relays. The
GRN
and
YEL
terminals are not used in relay mode.
In Relay Mode, the detector’s settings can only be modified using the DIP
switches and trimpot (see figure 2).
Combus Mode: (DIP switch 1 = ON)
When set to combus mode, the DG85 communicates alarm signals, tamper
signals, data and detector settings via the panel’s 4-wire combus.
The detector’s relay output always remains active even when set to combus
mode and can be used to activate other devices.
In combus mode, the motion detector can be modified using the DIP switches
and trimpot or by entering module programming mode.
In combus mode, the DG85 will respect the most recent modification whether it
is made through the DIP switches and trimpot or through section programming.
As a result, current DIP switch and trimpot positions may not represent actual
settings. All settings are stored in the DG85 even after it has been powered
down.
Figure / Figura 1
Installation / Instalación
Figure / Figura 2
PCB Connection and Setup / Conexión y Configuración de la PCI / Connexion et
configuration de la carte de circuits imprimés
Technical Specifications
Protection Level:
I P45
Sensor type:
Dual Element Infrared X 2
RFI / EMI rejection:
10V/m
Sensor geometry:
Rectangular
Voltage input:
9 to 16Vdc
Current consumption: 30mA Maximum
Anti-tamper switch:
150mA/28Vdc, N.C
Lens:
2nd generation
Fresnel lens,
LODIFF®, segments
Alarm output:
Form A relay
100mA28Vdc, N.C. or
optional form C relay 5A/
28Vdc, N.C./N.O.
Detection speed:
0.2m/s to 3.5m/s (0.6ft/s to 11.5ft/s) Ingress
Operating temperature:-35°C to +50°C (-31°F to +122°F)
© 2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice.
One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259,
5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply.
Canadian and international patents may also apply. LODIFF® lens: patent #4,787,722 (U.S.).
Digigard is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada,
the United States and/or other countries.
LODIFF® is a registered trademark of Fresnel Technologies Inc.
Warranty: For complete warranty information on this product please refer to the Limited Warranty Statement
found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance
of all warranty terms and conditions.
Figure / Figura 3
DG85W Pet Array Beam Pattern / Modelo Inmune a Mascotas Estandar DG85W
/
Diagramme de lentilles Couloir pour animaux DG85W
Figure / Figura 4
DG85L1 Horizontal Curtain Beam Pattern / Modelo Pasaje de Mascotas DG85L1 /
Diagramme de lentilles Rideau horizontal
DG85L1
Figure / Figura 5
DG85L2 Vertical Curtain Beam Pattern/ Modelo Cortina Vertical DG85L2 /
Diagramme de lentilles Rideau vertical DG85L2
Detector Settings
Walk-testing
At 20°C (68°F), at the highest sensitivity setting and in Single Edge Processing mode,
you should not be able to cross more than one complete zone (consisting of 2 beams,
left and right sensor detecting elements) in the coverage area with any kind of
movement; slow/fast walking or running.
At the lowest sensitivity setting, the amount of movement required to generate an
alarm is doubled. The approximate width of a full beam at 11m (35ft) from the detector
is 1.8m (6ft). To walk-test, move across the detection path, not toward the detector.
Detector
Beam Pattern
DG85W
Pet Array beam pattern (see figure 3)
DG85L1
Horizontal Curtain beam pattern (see figure 4)
DG85L2
Vertical Curtain beam pattern (see figure 5)
' * 6 ( 5 , ( 6
Printed in China - 10/2007 paradox.com DG85-TI06
Instructions
Instrucciones
Outdoor Digital Dual-Optic High-
Performance PIR V1.3
C
C
A
A
A
A
B
B
B
B
E
D
A
-Corner mount
-Montaje en esquina
-Montage en coin
B
-Flat surface mount
-Montaje superficie plana
-Support pivotant
C
-Swivel mount bracket
-Soporte de montaje giratorio
-Support pivotant
D
-Wire entry
-Entrada de cableado
-Entrée de fils
E
-Insert foam protection into wire entry
-Insertar la espuma de protección en entrada
de cableado
-Insérer de la mousse protectrice à l’entrée }
des fils
E
-Align height with tab
-Alinear altura con
lengüeta
-Aligner la hauteur
avec la languette
F
-Detect LED
-LED de detección
-DEL de détection
G
-Trimpot
-Potenciómetro
-Potentiomètre
H
-Electrical connectors
-Conectores eléctricos
-Bornes de
raccordement
I
-DIP switch
-Interruptor DIP
-Commutateur DIP
E
F
G
H
I
2,1m
(7ft)
A
B
C
D
A
-Anti-tamper switch
-Interrupt.
antisabotaje
-Interrupteur de
sécurité
B
-To Combus
Combus mode only)
-Al Combus (modo
DGP solamente)
-Au Combus mode
DGP seulement)
C
-Power input
(+12Vdc)
-Alimentación
(+12Vcc)
-alimentation
(+12 Vc.c.)
D
-Alarm relay
-Relé de alarma
-Relais d’alarme
Co
ver
age
In
st
al
la
tio
n
Hei
ght
Pe
t
Immu
ni
ty
DG85W
90°
11m x 11m
(35ft x 35ft)
2.1m
(7ft)
40kg
(90lbs)
DG85L1
(Horizontal)
85°
11m x 11m
(35ft x 35ft)
1.1m
(3.6ft)
Multi/large
pet
DG85L2
(Vertical)
5.64°
13m (43ft)
x 2 beams
2.1m
(7ft)
N/A
Ang
le
P
IW
R
7239,(:
6,'(9,(:
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
P
IW
7239,(:
6,'(9,(:
P
IW
P
IW
P
IW
P
IW
P
IW
7239,(:
6,'(9,(:
P
IW
P
IW
Step
Section /
DIP
Details
1
Operational
Mode
DIP
Switch 1
DIP switch 1 ON
=Combus mode (go to step 2)
DIP switch 1 OFF =Relay mode
U
(go to step 3)
2
Enter detector programming mode.
Press and hold
[0]
+
[
INSTALLER
CODE
]
+
[4003]
(EVO) or
[953]
(DGP-848) + SN (located on PCB cover).
3
Signal
Processing
Mode
Single edge processing should be used in normal
environments with minimal sources of interference. Dual
Edge Processing provides better false alarm rejection if the
detector is placed near sources of interference that can
adversely affect it.
[001]
or
DIP
Switch 2
[1] OFF
=Dual edge
[1]
ON
=Single edge
U
or
DIP switch 2 OFF
=Dual edge
DIP switch 2 ON
=Single edge
U
4
LED
Settings
LED flash = Movement without alarm (see step 5)
LED on 5 sec. = Movement with alarm
[001]
or
DIP
Switch 3
[2] OFF
=LED disabled
[2]
ON =LED
enabled
U
or
DIP switch 3 OFF
=LED disabled
DIP switch 3 ON
=LED enabled
U
5
Movement
Signal
Indication
When enabled and a signal is detected that matches the
characteristics of a movement signal, but does not reach
the required energy levels for an alarm, the LED flashes
once, indicating the signal was kept in memory.
Note: The LED must be enabled. (see step 4)
[001]
[3] OFF =Movement signal disabled
[3]
ON
=Movement signal enabled
U
Note: In relay mode, this feature is enabled if
DIP switch 3 = ON.
6
Tamper
Recognition
When enabled and the anti-tamper switch is open (cover
removed), the detector sends a tamper message to the
control panel via the combus.
[001]
[5]
OFF =Tamper
recognition
disabled
U
[5] ON
=Tamper recognition enabled
7
Sensitivity
The DG85 features adjustable sensitivity. Adjust from 0
(lowest sensitivity) to 10 (highest sensitivity).
Depending on the sensitivity setting, an alarm
condition can be generated between 0.25 sec.
(highest) and 2 sec. (lowest) after the actual
movement.
Viewing Sensitivity Settings
Remove the cover to view how many times the LED
flashes, then adjust the setting accordingly. The LED
flashes a consecutive amount of times to show the setting.
Thus if the sensitivity is set to 6, the LED flashes 6 times.
[002]
or
Trimpot
000 =Lowest sensitivity
010
=
Highest sensitivity
U
Turn clockwise
=Increase sensitivity
Turn counterclockwise
=Decrease sensitivity
U