Grill Island Preparation
•
15
Custom Built Island Ventilation
Every component within the grill island must be vented – refrigerator, LP
gas cylinder, etc. Vent locations must be determined by a licensed
professional according to the design and configuration of your island.
Figure 6 illustrates examples of possible venting locations for custom-
built grill islands.
Figure 6 Example Vent Locations
Custom Built Island Cut-outs
Ensure any island cut-out opening is no larger than the outside frame of the appliance being installed. The
appliance should rest on the lip of the frame.
Figure 7 illustrates sample cut-out sizes for a grill island. Here are some other considerations:
•
Ensure your grill island cavity is adequately vented. Consult your local licensed professional and local
codes for adequacy requirements
•
Ensure your outdoor kitchen is constructed out of non-combustible materials
•
If your outdoor kitchen is constructed of any combustible materials, an insulated jacket is REQUIRED
•
Cutout dimensions do not allow for lid clearance or other measurement requirements. Consult the
Operator Manual for specifics
•
Please allow for a tolerance of +/- 1/8"; we recommend having your appliances in hand to measure
before making final cutouts in your custom-built grill island