background image

2. 

Run the Landscape Wire (Not Included)                       

2. 

Installation du câble de jardin (non-inclus) 

The landscape wire should run from the transformer  

to each light without being cut. Do not run the  

landscape wire within 10 feet (3m) of a pool, spa or 

fountain. If the landscape wire is too long, cut it  

with a cable cutter.

The landscape wire should be protected by routing it 

close to proximity of the light fixture or next to a  

building, deck or fence. Use cable suitable for low volt-

age landscape lighting. 

See chart below for recommended cable gauges.

*Suitable cable should be sized in accordance to the table, should be Type SPT-2W.

If you cannot find this cable at your local hardware or home improvement store then

please call customer service at 1-888-867-6095 or e-mail at

[email protected] to order the cable needed.

 

Le câble pour jardin doit aller du transformateur à chaque 

luminaire sans être coupé. Ne pas faire passer   

le câble à moins de 3 mètres (10pi) d’une piscine, d’un 

spa ou d’une fontaine. Si le câble pour jardin est trop long, 

couper-le avec une pince coupe-câble.
Il faut protéger le câble pour jardin en le faisant passer  

près du luminaire ou de l’édifice, de la terrasse ou de la 

clôture.
Veuillez vous référer à la charte ci-dessous pour les  

grosseurs de câble appropriées. 

Le choix de la grosseur du câble doit être fait selon le tableau ci-joint et doit être   

de type SPT-2W. Si vous ne trouvez pas ce câble à votre magasin ou quincaillerie de  

quartier, alors contactez le service à la clientèle au 1-888-867-6095 ou par courriel au 

[email protected]

* llustration of fixtures is for example only.     

L’illustration des luminaires est à titre d’exemple seulement.

3.  Choosing Lighting Fixture Location

3.

 

Choisir l’emplacement du luminaire

For uniform brightness and longer bulb life,  

attach first fixture at least 10 feet from transformer.

  

Once you have decided where you will install your fixtures,  

verify the type of soil. 

 

If the soil is of a loose, sandy or organic type,

 grasp the fixture  

  post, close to the spike, with both hands and firmly push into 

  the ground. 

•  If the soil is heavy or stony,

 dig a small hole, insert the fixture 

  spike, replace the soil and tap down. 

Never push the fixture into the ground by the fixture head.

Pour un éclairage uniforme et pour allonger la vie de l’ampoule,  

installer le premier luminaire à au moins 3 mètres du transformateur. 

 

Une fois l’emplacement des luminaires déterminé, examiner la nature  

du sol.

•  Si le sol est meuble, sablonneux ou organique,

 prendre le pied  

  du luminaire près du piquet à deux mains et l’enfoncer fermement  

  dans la terre. 

•  Si le sol est lourd ou pierreux,

 creuser un petit trou, insérer le  

  piquet du luminaire, remplir le trou avec la terre et bien tasser.

Ne jamais enfoncer le luminaire dans la terre en le tenant par la tête.

 

Luminaires

Fixtures

Cable

Câble

Transformer

Transformateur

Combined wattage of all fixtures on line (in 

Watts)

Wire Gage (0-75') Wire Gage (75'-150')

Wire Gage (150'-250')

0-60

16

16

12

60-120

16

12

12

120-180

12

12

12

180-240

12

12

Not recommended

240-300

12

Not recommended

Not recommended

Calibre del cable

(75'-150')

Calibre del cable

(0-75')

Calibre del cable

(150'-250')

0-60

16

16

12

60-120

16

12

12

120-180

12

12

12

180-240

12

12

240-300

12

Voltaje combinado de todas las lámparas

(en vatios)

No recomendado

No recomendado

No recomendado

Gauge du fil

 (0-75')

Gauge du fil

 (75'-150')

Gauge du fil

 (150'-250')

0-60

16

16

12

60-120

16

12

12

120-180

12

12

12

180-240

12

12

240-300

12

Wattage total de tous les luminaires sur la 

ligne (en watts)

Pas recommandé

Pas recommandé

Pas recommandé

4.2

 Align and fit the main low 

voltage cable vertically to the slot 

of wire connector as shown.

4.2

 Aligner et installer le câble bas 

voltage verticalement dans la fente 

tel qu’illustré.

4.3

 Press the wire connector together until fully 

seated and locked around the cable. Pre-set 

prongs will pierce the cable insulation and 

establish contact. Turn on the power unit. If the 

light fixture does not turn on, repeat operations 

4.2 and 4.3.

4.3

 Presser le connecteur de chaque côté 

jusqu’à qu’il soit bien installé et sécurisé. Les 

pointes du connecteur vont percer la gaine 

du câble pour établir un contact. Mettre sous 

tension. Si le luminaire ne s’allume pas, répéter 

les étapes 4.2 et 4.3.

4.4 

Once the clip-on connector is in place, wrap 

it with electrical tape for additional protection.

4.4 

Une fois le connecteur en place, enveloper 

le de ruban électrique pour une protection 

supérieure.

4.

 Connect the fixture wire to the landscape wire

     

Connexion du câble du luminaire au câble pour jardin

4.1

 Place the wire connector on 

opposite sides of the low voltage 

cable where the fixture will be 

located.

4.1

 Placer le connecteur de chaque 

côté du câble bas voltage où sera 

installé le luminaire.

ATTENTION 

SOYEZ PRUDENT ! 

LES POINTES DES 

CONNEXIONS SONT 

TRÈS ACÉRÉES !

CAUTION

 

BE CAREFUL!

THE WIRE STABS

ARE VERY

SHARP!

Summary of Contents for GL22601

Page 1: ...ens or bulb protector WARNING Risk of Electric Shock Install all luminaires 10 feet 3 05 m or more from a pool spa or fountain Install in accordance with all local codes and ordinances Only for use with low voltage power units with a maximum output rating of 15V 300W per secondary INSTRUCTIONS PERTINENTES CONCERNANT LES CAUSES DE BRÛLURES OU DE BLESSURES IMPORTANTES INSTRUCTIONS DE SÉCURITÉ Une am...

Page 2: ... montre 1 1 Carefully remove the fixture from its protective packaging 1 2 Insert the bulb into the bulb socket Use a soft cloth as oil from skin may damage the lamp bulb 1 3 Attach the spike to the body by turning clockwise 1 Assembly of the Light Fixture 1 Assemblage du luminaire Top cap Embout Glass diffuser Diffuseur en verre Spike Piquet Gasket Joint d étanchéité Body Corps 20W Halogen MR11 B...

Page 3: ...r luminaire à au moins 3 mètres du transformateur Une fois l emplacement des luminaires déterminé examiner la nature du sol Si le sol est meuble sablonneux ou organique prendre le pied du luminaire près du piquet à deux mains et l enfoncer fermement dans la terre Si le sol est lourd ou pierreux creuser un petit trou insérer le piquet du luminaire remplir le trou avec la terre et bien tasser Ne jam...

Page 4: ...orter votre produit à l endroit où vous l avez acheté pour un remboursement total ou le remplacement du produit Le consommateur assume la responsabilité du retrait et de la réinstallation du produit Toutes pièces endommagées à cause d un accident d une mauvaise utilisation ou d une mauvaise installation NE SONT PAS couverts par cette garantie Notre garantie ne couvre pas les dommages directs ou in...

Reviews: