Quantum and Evolution Series Installation and Operating Handbook
13-13
Monitor
0-10V analogue output (Signal level, Eb/No, or Rx
offset frequency) on Alarms & AGC connector
Buffered constellation monitor port on Async ESC
connector
Mechanical
1U chassis – 410mm deep, excluding front panel
handles and rear panel connectors and fans
.
Weight
3.5 Kg
Power Supply
100-240VAC, -10%, +6%, 1A at 100V, 0.4A at
240V, 47-63Hz.
Fused IEC connector (live and neutral fused).
48 Volts DC option
Safety
EN60950-1
EMC
EN55022 Class B (Emissions)
EN55082 Part 1 (Immunity)
Environmental
Operating Temperature Range 0-50ºC
Mains data
AC Mains inrush surge current at power up = 25A
@ 250V
Modem uses 3.15A slow blow fuses in all cases.
Maximum power consumption fully loaded is
approx 105W.
Earth leakage current is approx 2mA @250V
13.16 Internet
Traffic
Parameter
Modem
Standard
(unaccelerated)
Throughput depends on traffic format – formats
such as UDP that do not require
acknowledgements run at up to the maximum data
rate of the modem – unaccelerated TCP (which
requires acknowledgements) will typically run at up
to 128kbps per connection, 80 Connections/Sec
13.17
BUC / LNB facilities
Parameter
Modem
BUC Power Supply
Options
Mains input, +48V DC 2A output (100W) to BUC via Tx IFL
Mains input, +24V DC 4A output (100W) to BUC via Tx IFL
Mains input, +48V DC 3.5A output (180W) to BUC via Tx IFL
Mains input, +24V DC 6A output (180W) to BUC viaTx IFL
+48V DC input, +48V DC 3.5A output (180W) to BUC via Tx IFL
+48V DC input, +24V DC 6A output (180W) to BUC viaTx IFL
LNB Power
+15/24V 0.5A DC to LNB via Rx IFL (standard)
FSK Control Option
Requires a BUC Power Supply to be fitted.
Allows monitor & control of a compatible BUC from
the Modem, via the IFL
10MHz Reference via
IFL Option
Requires the High Stability 7.5x10
-8
/yr Reference
Oscillator Option.
10MHz may be provided via the Tx IFL to the BUC
and via the Rx IFL to the LNB