Quantum and Evolution Series Installation and Operating Handbook
7-147
Units:
dB
Minimum value:
0.1
Maximum value:
9.9
Step size:
0.1
Factory default:
0.1
Description:
When AUPC is active, sets the trip threshold at which a fault is declared
when the distant end Eb/No is outside the limit.
Edit-Unit-Advanced-Alarms-Thresholds-Dropped TRAU Count Threshold Screen
Units:
None
Minimum value:
0.0
Maximum value:
9999.0
Step size:
1.0
Factory default:
9999.0
Description:
Sets the error-rate threshold for dropped TRAU frames above which a
dropped TRAU alarm will be generated when using the Sat-ABIS
interface card.
Edit-Unit-Advanced-Alarms-Actions Screens
A number of screens are available that control the following:
•
Tx/Rx AIS.
These control the action taken with respect to Alarm Indication Signal
detection. AIS can be ignored or set to raise an alarm, regenerate AIS and send a
backward alarm where possible.
•
BER
. Controls whether the BER threshold alarm is enabled.
•
BUC PSU
. Controls whether the combined over/under-current, over-temperature
alarm for the Tx DC switch is considered a fault or not.
•
Handshaking
. Controls the action taken when a terrestrial handshake signal is
activated. It can be ignored or set to raise an alarm.
•
Clr 1:1 Alm
. Allows the user to temporarily clear a modem alarm that is preventing a
1:1 changeover.
TRAU threshold: 0.0 to 9999.0
[9999.0] Step 1.0
New: 10.0