13
Table 6-2 Test Equipment Required
Nomenclature
Manufacturer
Model
Network Analyzer
Agilent
8753 ET
Spectrum Analyzer
Agilent
8560E
Power Meter
Agilent
E4418B
Power Meter/Sensor
Agilent
437B / 8481A
Signal Generator
RDL
IMD-801D-03A
Directional Coupler
Agilent
778D
Attenuator
Weinschel Corp
53-30-34
Attenuator
Narda
766-20
6.4 Performance Test
Performance test should be performed every 12 months to ensure that the amplifier meets
the operational specifications.
NOTE
The frequencies used in this test are typically within the operating 5 MHz band of 935
MHz to 940 MHz. Select evenly spaced F1, F2, F3, and F4 frequencies that cover the
instantaneous bandwidth of your system.
Figure 6-2