![Par-Kan Grain-Weigh GW200A User Manual Download Page 12](http://html.mh-extra.com/html/par-kan/grain-weigh-gw200a/grain-weigh-gw200a_user-manual_752741012.webp)
12
Grain-Weigh 200A Trouble Shooting
Problem
Cause
Test
Correction
Engine will not start
No fuel
Bad connections
Dead Battery
Starter
Visual
Meter
Meter
Meter
Add fuel
Clean or replace
Charge or replace
Repair or replace
Selective hydraulic components not
working (Auger Screw, Unloading Door,
or Auger Tube Display)
Hydraulic Oil
Solenoid or Elec-
trical Connec-
tions
Hydraulic Com-
ponents
Visual
Check the meter con-
nection or switch that is
not working correctly.
Add oil
Fix faulty electrical con-
nection or switch
Replace faulty hydraulic
component(s)
Digi-Star Indicator will not power up
Blown fuse
Bad connections
Dead Battery
Other
Meter
Meter
Meter
Replace
Clean or replace
Charge or replace
See Digi-Star Manual
Auger speed slow
Plugged oil filter
Carrier bearing
adjustment
Visual
Visual or Heat
Replace
Adjust
Hydraulic oil overheating
Engine over
3,000 RPM
None
Keep engine at 3,000
RPM
All Hydraulics will not operate
Blown Fuse
Oil
Visual
Replace 10 amp fuse be-
hind weigh head.
Add Oil
Summary of Contents for Grain-Weigh GW200A
Page 5: ...5 Grain Weigh 200A Dimensions ...
Page 15: ...15 Grain Weigh 200A Axle Hub Assembly ...
Page 19: ...19 Grain Weigh 200A Frame Body Front View ...
Page 24: ...24 Grain Weigh 200A Electrical Schematic ...
Page 25: ...25 Grain Weigh 200A Electrical Schematic ...
Page 26: ...26 Grain Weigh 200A Electrical Schematic ...
Page 27: ...27 Grain Weigh 200A Electrical Schematic ...
Page 28: ...28 Grain Weigh 200A Hydraulic System ...
Page 29: ...29 Grain Weigh 200A Hydraulic System ...
Page 32: ...32 Grain Weigh 200A Shurco Roll Tarp Replacement Parts ...
Page 34: ...34 Model EZ2500 INDICATOR ...