![Paperfox FTD-1T Instruction Manual Download Page 9](http://html1.mh-extra.com/html/paperfox/ftd-1t/ftd-1t_instruction-manual_4393195009.webp)
Settings screen - 3
The speed can be selected by touching the speed buttons. (0-3)
The scale factor for the active speed can be modified.
If you enter the actual length of the paper in the Real length field, after pressing the "calculate scale
factor from real length" button, the machine will calculate and store the calculated value of the
scale factor.
The Measured length (ms) is the time during the sheet is under the photosensor.
The Measured length (mm) is the distance calculated from the time during the sheet is under the
photosensor and the scale factor.
The value of the scale factor is a distance in mm which the conveyor belt travels under 10 sec.
PAPERFOX FTD-1T TOUCHSCREEN CONTROLLER