background image

Troubleshooting 

 

Problem 

Possible Cause 

Solution 

The girdle is plugged in 

and turned on, 

however the green 

light doesn’t 

illuminate 

1.

 

The fuse has blown 

2.

 

The power cord is 

not correctly 

connected. 

1.

 

Replace the fuse 

2.

 

Confirm the power 

cord is correctly 

connected. 

The yellow indicator 

stays on and the 

temperature cannot 

be adjusted. 

1.

 

The connection of 

the yellow indicator 

is damaged. 

2.

 

The thermostat is 

broken. 

1.

 

Check the wiring 

for the yellow 

indicator 

2.

 

Replace the 

thermostat 

The yellow indicator is 

not illuminated, but 

temperature control 

functions normally. 

1.

 

The contact for the 

indicator is not 

functioning. 

2.

 

The indicator is 

burned out. 

1.

 

Check the 

connection. 

2.  Replace the 

indicator. 

 

Circuit Diagram 

 

 

 

 

 

 

 

 

 

 

 

 

 

ST

TEMPERATURE CONTROL   

HL2

HEATING INDICATOR (YELLOW)       

EH

HEATING ELEMENT   

 

E

GROUND PROTECTION 

HL1

POWER INDICATOR (GREEN) 

Summary of Contents for G1

Page 1: ...Griddle G1 Operating Manual ...

Page 2: ...f the supply The machine must be earthed when used There is a danger of electric shock if it is not earthed In case of emergency please turn off the power switch and unplug the machine If the electric wire becomes damaged a qualified engineer or the manufacturer must replace it Pantheon Catering Equipment is not responsible for any accidents or faults caused by amendments made to the machine or im...

Page 3: ...erature reaches the set temperature the thermostat switches off the heat and the yellow indicator goes out 4 When the temperature drops below the temperature that has been set the thermostat switches the heat on again 5 This process repeats in order to maintain the required temperature 6 Adjust the temperature control dependent on the type of food being cooked in order to get the best results 7 Wh...

Page 4: ...e cannot be adjusted 1 The connection of the yellow indicator is damaged 2 The thermostat is broken 1 Check the wiring for the yellow indicator 2 Replace the thermostat The yellow indicator is not illuminated but temperature control functions normally 1 The contact for the indicator is not functioning 2 The indicator is burned out 1 Check the connection 2 Replace the indicator Circuit Diagram ST T...

Page 5: ...arts Diagram No Description 1 Bolt foot 2 Rubber foot 3 Screw base 4 Bottom Plate 5 Nut 6 Outer Plate 7 8 Inner Plate 9 Nut 10 Element Support 11 Element 12 Body Shell 13 Plug Mains Cable 14 Cable Gland ...

Page 6: ...15 Thermostat 16 Front Cover 17 Bezzel for Temperature Knob 18 Screws 19 Indicator 20 Indicator 21 Control Knob 22 Bottom Panel for Electric Box 23 Screws 24 Drip Tray 25 Drip Tray Housing ...