G310 Service Manual
PANTECH
R&D
CONFIDENTIAL
30
6.1.2 Oscillation CHECK
1. Check to see if U101 No. A3 and B3 pin is oscillated(32.768KHz) : CP108
NO Check R138 and then replace X101
2. Check to see if U107.4 pin Master Clock(13MHz). : CP109
NO Check U107 No. 1.2 pin and then check the PCB pattern, soldering
CP108
CP108
CP109
CP109