Mobility 
 
The large diameter (100 mm) of four independent castors allows excellent manoeuvrability of the 
table. Especially in small and angular corridors this will help a lot. Each castor is single lockable. All 
castors are lockable (in moving and rotation). To lock or unlock press or release the lever. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Battery System with Charger 

 
Special attention should be given to the battery system. 
 
In order to achieve the longest life span it is recommended to recharge the battery over night after 

every day’s operation. Try to avoid discharge depth of 100% too often; it will shorten the life span of 

your  battery  system.  Less  discharging  depth  means  longer  life  span  of  your  battery. 

To  load  the 

battery, you have to take out the battery from the table. To take out the battery pull the lever. To 
load  the  battery,  connect  the charger  to  the charging  socket.  To  load  a  battery  completely  it  can 
take up to 5 hours. This time depends on how deeply unloaded the battery is. It is also possible to 
use  two  different  batteries.  Please  ask  your  dealer  for  a  quotation.  The  battery  is  fully  charged 
when the LED on the charger is green. When you put back the bat

tery you need to hear a „CLICK“; 

then the battery is connected correctly to the control box. 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

Unlocked 

Locked 

Charger 

Connect charger to the battery 

Summary of Contents for X-Lifter

Page 1: ...sstrasse 15 A 7423 Pinkafeld AUSTRIA Page 1 of 9 Tel 43 3357 42277 Fax 43 3357 42277 4 Version 1 0 e mail office panno med at Internet www panno med at X Lifter OPERATING INSTRUCTIONS Please read thro...

Page 2: ...tant to read the following instructions carefully before using your new equipment TECHNICAL DATA Height adjustment 26 to 97 cm Table top dimensions 130 x 60 cm Load capacity electric 80 kg Power suppl...

Page 3: ...recommended to recharge the battery over night after every day s operation Try to avoid discharge depth of 100 too often it will shorten the life span of your battery system Less discharging depth me...

Page 4: ...h with vinegar followed by a neutralising rinse with clear water and a thorough drying with a soft cloth Avoid prolonged standing of chlorides chlorine bleach bromides iodides and thiocyanates on stai...

Page 5: ...n solve the problem Switches Check if all cables are correctly connected to the control box Also please check and be sure that a cable is not squeezed or destroyed Before you disassemble the switches...

Page 6: ...tuator and for the switches The control box is screwed with one small screw and hooked at the other side To take out the control box move it to the end of the table To install a new control box please...

Page 7: ...take out the actuator from the table please lay the table to the side This position prevents the scissor from collapsing Remove the safety rings from the bolts Take out the bolts and the actuator fro...

Page 8: ...on 1 0 e mail office panno med at Internet www panno med at Castor To change the castor please unscrew it from the castor holder After that please mount the new castor with the delivered screw and nut...

Page 9: ...med at Changing the top To change the top please unscrew it from the frame Remove the old top and put the new top on the frame Fix it with the screws The top is fixed with 6 screws It is not necessar...

Reviews: