background image

INSTRUCTIONS CM365

For Technical Support: www.panduit.com/resources/install_maintain.asp

5

3/8” dia hanger wire
mounting holes
(8 places)

3/8” dia hanger wire
mounting holes
(4 places)

5.1

Hanger wire should be used to hang the enclosure 
within a suspended ceiling. 

Important: 

Verify hanger 

wire meets local building code. Weight of the 
enclosure, mounting brackets, and equipment does not 
exceed 20 lbs. The enclosure is rated to hold up to     
10 lbs of equipment.

5.2

Observe how the hanger wire used to hold the ceiling 
support grid is secured to the building structure. 

5.3

Remove one tile adjacent to the tile the enclosure will 
be mounted in.

5.4

Secure four pieces of hanger wire (not included) to the 
building structure. The hanger wire length will be 
determined by the installer based on the building 
structure dimensions above the suspended ceiling. 
Extend the length of the hanger wire beyond the 
surface of the ceiling by at least 6".

5.5

Add the cut ceiling tile back to the ceiling support grid.

5.6

Pull one of the four pieces of hanger wire to one corner 
of the square opening in the ceiling tile. Pre-bend the 
hanger wire at a 90° angle approximately 2 1/2” above 
the surface of the ceiling tile. Repeat this step for the 
remaining 3 hanger wires measuring to the three 
remaining corners of the square opening.

5.7

Insert the enclosure into the cut ceiling tile opening.

5.8

While holding the enclosure flush with the surface of 
the ceiling tile, route the hanger wire through one of the 
eight 3/8” dia hanger wire mounting holes and bend up. 
Pull the wire upward until the enclosure is flush with the 
ceiling tile. Repeat this step using the three remaining 
hanger wires to secure the three remaining corners of 
the enclosure.

5.9

Visually inspect the edges of the enclosure to verify no 
gaps exist between the mounting brackets and surface of 
the ceiling tile. If gaps exist, pull the hanger wire upward 
until the enclosure is tight against the ceiling tile.

5.10 To secure the enclosure, wrap each hanger wire tightly 

around itself a minimum of three times.

5.11 Replace the adjacent ceiling tile.

Step 5: Hanging Enclosure in Bracket

Page 4 of 8

6.1 Run cable from the Telecommunications Grounding 

Busbar (TGB) to the enclosure and attach to the 
grounding stud on the base.

6.2 Using the supplied Grounding Cable, attach one end to 

the grounding stud on the base (on top of TGB cable) 
and the other end to the grounding stud on the door.

6.3 Secure with the #10 Split Lock Washers and #10-32 Hex 

Nuts.

Step 6: Grounding

6

Grounding
Studs

Summary of Contents for PZWIFIEN

Page 1: ...et Edging 1 2 Position Surface Mount Box PANDUIT Part No CBXJ2WH A PZWIFIEN ONLY 1 2 long Category TX6 Plus Patch Cord PANDUIT Part No UTPSP2 1 Category TX6 Plus Jack Module PANDUIT Part No CJ688TGWH...

Page 2: ...enna configuration Please read these instructions in their entirety prior to installing the enclosure 2 x 4 Stud 1 PANDUIT Part PZWIFIDCB PANZONE Wireless Access Point In Ceiling Bracket Kit PANDUIT P...

Page 3: ...is approximately 12 7 8 x 14 5 8 must be cut in the ceiling tile 3 2 It is important that the hole be no smaller than 12 5 8 x 14 3 8 and no larger than 13 1 8 x 14 7 8 This will ease installation an...

Page 4: ...the surface of the ceiling tile Repeat this step for the remaining 3 hanger wires measuring to the three remaining corners of the square opening 5 7 Insert the enclosure into the cut ceiling tile open...

Page 5: ...t per manufacturers instructions to the mounting bracket as shown in Figure 7 2 3 Install dipole antennas as shown in Figure 7 3 for wall mounting applications 4 Install dipole antennas as shown in Fi...

Page 6: ...10 3 Press down on the foam and slide the foam retention plate into place The expanding foam holds the reten tion plate in place Step 10 Install Fire Resistant Foam if needed 8 1 Run the network cabl...

Page 7: ...Reverse the mount plate by removing 4 6 32 screws and fastening the mount plate to the enclosure base using the short mount flange 1 3 Install access point as shown in Figure 1 2 for wall mounting app...

Page 8: ...n 2 Wireless Access Point with External Antennas Alternate In Ceiling Installation 2 1 Remove RP TNC knockouts as shown in Figure 2 1 for in ceiling mounting 2 2 In order to use bulkhead extender cabl...

Reviews: