Page 1: ...MN028 Version 2 0 Panduit PViQ Switched POU User Manual Switched and Environmental Monitored Switched with Per Outlet Power and Environmental Monitored...
Page 2: ...hotocopying recording or otherwise without written permission from PANDUIT No patent liability is assumed with respect to the use of the information contained herein Although every precaution has been...
Page 3: ...tup 11 WEB INTERFACE 13 Overview 13 Sensors Page 13 Logging Page 15 Display Page 16 Alarms Page 17 Control Page 18 Control Actions Tab 18 Control Settings Tab 19 Configuration Page 20 Configuration Ne...
Page 4: ...35 Connecting Remote Sensors 36 Data Logging and Display 36 REMOTE OUTLET SWITCHING 37 Actions 37 Configuration 38 Power On Actions 38 ACCESSORIES 39 Remote Display 39 IP Addressable Network Cameras...
Page 5: ...s plus additional current sensors to monitor individual outlet current Optional external sensors and network cameras are also available Environmental Temperature Operating 10 C 50 F min 45 C 113 F max...
Page 6: ...o the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This C...
Page 7: ...er current conditions A Listed circuit breaker is required within the building installation The circuit breaker should be sized according to the POU s nameplate ratings and local national electrical c...
Page 8: ...Strip Mounting Brackets can also be mounted to the rear equipment rails To center the 66 25 vertical power strips For 7 foot post racks mount L Bracket at RU spaces 03 and 43 For 8 foot 4 post racks m...
Page 9: ...PViQ Switched POU Version 1 0 9 Toolless Mounting Hardware Use toolless buttons with key holed slots built into cabinet or with optional key holed brackets...
Page 10: ...PViQ Switched POU 10 Version 1 0 Panduit Cabinet CS3...
Page 11: ...rk connector will restore the default IP address and will also clear all password settings The Configuration page allows you to assign the network properties or use DHCP to connect to your network Acc...
Page 12: ...PViQ Switched POU 12 Version 1 0 Typical Network Card Settings for PC or Laptop to connect to default IP address...
Page 13: ...The front page Sensors gives both instantaneous and historical views of the unit s data Real time readings are provided for all power strip data outlet group data and sensor data next to historical gr...
Page 14: ...PViQ Switched POU 14 Version 1 0...
Page 15: ...onal remote display module Checked readings in the Logged Measurements section are logged into the data file at a rate of one point per minute and will be available for graphing and display Note that...
Page 16: ...ors as well as change the default temperature unit of measure for external sensors The display page also allows the user to select between the default and classic web page layouts The default interfac...
Page 17: ...establish alarm conditions for each sensor reading Alarm conditions can be established with either high or low trip thresholds The alarms are displayed in different sections based on the device the al...
Page 18: ...page has two sub tabs Actions and Settings See Remote Outlet Switching for details Control Actions Tab The Actions tab on the Control page gives the user control of the outlets Outlets can be reboote...
Page 19: ...ws the user to name and define a URL for outlets in addition to setting time delays for each outlet action Boot up status and sequential boot up options are also available All delay settings are refer...
Page 20: ...ge has five sub tabs Network Monitoring Diagnostics Event Log and Admin See Unit Configuration for details Configuration Network Tab The user can enter and update the network settings on the Network t...