OPERATION INSTRUCTIONS

PPTEH

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Tool will not operate. No air pressure at tool.

Verify that air supply is “on”, and that connections are good
to be sure that tool is receiving air.

Tool  will  not  cut  off
cable tie.

A.  Air pressure too low.

B.  Tool has reached end of stroke.
C.  Tool cutter blade is broken or dull.

A.  Check  air  supply  regulator  for  proper  adjustment.

Increase air pressure if necessary.

B.  Release trigger and squeeze again.
C.  Replace blade using KPPTEHB Blade Replacement Kit.

Contact Panduit.

Gripper will not return
to forward position.

Material wedged in nose area.

Depress trigger and maintain in a depressed position while
removing materials from nose area.

Cable tie is slipping in
gripper.

Gripper is worn or damaged.

Replace gripper using KPPTEHG Gripper Replacement
Kit.  Contact Panduit.

Cable  tie  is  too  loose
on bundle.

A.  Tool tension setting is too low.

B.  Operator  holding  tool  at  angle  to

bundle.

C.  Tool  is  held  away  from  bundle  by

previously  installed  cable  tie,
harness support, or other object on
bundle.

D.  Tool  is  pulled  on  as  tie  is  being

tensioned.

A.  Check selector knob for proper setting for specific cable

tie being applied (See Tension Adjustment).

B.  Hold tool perpendicular to bundle in both directions.

C.  Do  not  install  cable  ties  too  close  to  other  cable  ties,

harness supports or other objects on bundle.

D.  Allow  tool  to  seek  its  own  position  as  the  tie  is  being

tensioned.

Cable  tie  is  too  tight
on bundle.

Tool tension setting is too high.

Check selector knob for proper setting for specific cable tie
being applied (See Tension Adjustment).

Cable ties will not stay
on bundle.

Wire bundle exceeds maximum diame-
ter for specific tie being applied.

Operator should dress the wires to result in a more compact
bundle.

Air leaks from tool.

A.  Loose or bad fittings.
B.  Worn or bad hoses.
C.  Worn or bad air cylinder assembly.

Contact Panduit.

E-mail:

[email protected]

EU Website:

www.panduit.com/emea

EU Email:

emeatoolservicecenter

@panduit.com

Technical Support:

Panduit Electrical Headquarters (USA)

16530 W. 163rd Street

Lockport, IL 60441 U.S.A.

1-800-777-3300

Panduit EMEA Service Center (EUR)

EMEA Tool Service Center

Bedrijvenpark Twente 360 

7602 KL Almelo 

tel + 31 546 580 451

www.panduit.com

NOTE:  In the interest of higher quality and value, Panduit products are continually being improved and updated.
Consequently, pictures may vary from the enclosed product.

Reviews: