For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS PN256D
1.6
ITEMS REQUIRED FOR TERMINATION
ITEM
PART
NUMBER
DESCRIPTION
1
CST-115
Fiber Cable Jacket Stripper
2
FALC
Alcohol Bottle (empty)
3 FBFSP
Fiber
Buffer
Stripper
4 FCRP5
Universal Crimp Tool (hex sizes: .048, .100, .128, .151, .190) Hex sizes needed for
M
INI
-C
OM
O
PTI
-J
ACK
termination:
.128 and .151
5 FCVR
Fiber
Cleaver
6 FGLS
Safety
Glasses
7
FJPKGU
Universal Polishing Puck
8 FJPMR Primer
9 FJPXY
Anaerobic
Adhesive
10
FKS
Strength Member (Aramid Fiber) Cutters
11 FPAD
Polishing
Pad
12
FPP5-L
5µm Polishing Film (Aluminum Oxide)
13 FSCDVR Screwdriver
14
FSTY
Safety Stickers for fiber scraps
15 FSWB-C Cleaning
Swabs
16
FSYR-X
Syringes with needle tips
17 FTWZR
Tweezers
18 FWP-C
Cloth
Wipes
19
PFX-0
Indelible Ink Marking Pen
20
FLOUPEX10
Eye Loupe 10X Power
21
FPF1-V
1µm Diamond Polishing Film
22
FLPT
Crimp Tool (For 2.0mm/1.6mm terminations only)
23
FHSCT
110VAC/60Hz Heat Shrink Curing Tool (For 2.0mm/1.6mm terminations only)
24
--
Isopropyl Alcohol (Reagent Grade, 90% minimum concentration; not available from
PANDUIT
)
25
FLCFPLF-X
.05µm Lapping Film (For singlemode terminations only)
26
FWBTL
Distilled Water Bottle (empty)
27
--
Distilled Water (not available from
PANDUIT
)
OPTIONAL
FHSCT-W
230VAC/50Hz Heat Shrink Curing Tool (For 2.0mm/1.6mm terminations only)
OPTIONAL
FJJ9FRL-X
Replacement ferrule and crimp sleeve for
O
PTI
-J
ACK
singlemode jack (10)
OPTIONAL
FJEP9FRL-XY
Replacement ferrule and crimp sleeve for
O
PTI
-J
ACK
singlemode plug (10)
OPTIONAL PN257
Stripping
Template
Page 2 of 8
2. PRECAUTIONS
2.1
SAFETY GLASSES
WARNING
: Safety glasses have to be worn when handling the adhesive or primer used with the connector or when han-
dling bare optical fiber. The bare fiber is very sharp and can easily damage the eye.
2.2
ISOPROPYL ALCOHOL
WARNING
: Isopropyl alcohol is flammable. Contact with the alcohol can cause irritation to the eyes. In case of contact
with the eyes, flush with water for at least 15 minutes. Always use isopropyl alcohol with proper levels of ventilation. In
case of ingestion, consult a physician immediately.
2.3
RECOMMENDED ADHESIVE AND PRIMER
WARNING
: The recommended adhesive (
PANDUIT
Part #FJPXY) may contain maleic acid and methacrylic ester. In
case of eye contact, flush with water for 15 minutes and get medical attention. Wash after skin contact. Request M.S.D.S.
for further safeguards. Check “Used By” date on bottle to ensure best performance.
WARNING
: The recommended primer (
PANDUIT
Part #FJPMR) may contain acetone. The primer is harmful if inhaled
or swallowed. In case of contact with eyes or skin, flush with water. Get medical attention in case of ingestion or contact
with eyes. Do not induce vomiting. Check “Used By” date on bottle to ensure best performance.
2.4
DISPOSAL OF BARE FIBERS
WARNING
: Pick up and discard all pieces of bare fiber with sticky tabs. Do not let cut pieces of fiber stick to clothing or
drop in the work area where they are hard to see and can cause injury.
2.5
LASER LIGHT PROTECTION
WARNING
: Laser light is invisible. The invisible light is powerful enough to damage your eyes. Serious damage to the
retina of the eye is possible. Never look into the end of a fiber which may have a laser coupled into it. Should accidental
eye exposure to laser light be suspected, arrange for an eye examination immediately.
2.6
CABLE HANDLING
WARNING
: Fiber optic cable can be damaged by excessive pulling, twisting, crushing or bend-
ing stresses. Consult the appropriate specification sheets as provided by your cable vendor.
Any damage may result in decreased optical performance.