4. MAINTENANCE
The CTFP-100 must be
opened. Disconnect
compressed air!
4.1 ....... Cleaning
•
Unscrew hexagon socket screw (1).
•
Pull out the die set (2).
•
Clean die set (3) and lightly oil pivot (4).
•
Push in die set (5).
•
Tighten hexagon socket screw (6).
Figure 4 - Cleaning
4.2 Lubrication
•
Unscrew the head (1).
•
Remove the spring (2) and piston (3).
•
Lubricate the two arms of the die set (4)
(e. g. CHEMPLEX 746).
•
Insert piston and spring.
•
Insert head (5) and fasten fingertight.
•
Pay attention that the arms of the die set
(4) are correctly engaged in the piston
(3).