STORAGE AND TRANSPORT 

Always store the tool in its clean, dry carrying case when not in use, and during transport. 
The battery cartridge and the battery charging unit should be protected against humidity and dust. 

 
 

TROUBLESHOOTING 

Before You Begin: 

1. 

Make sure that the battery is charged.  Recheck the battery after several minutes to make 
sure the battery is holding its charge. 

2. Use 

nonflammable

 contact cleaner or pencil eraser to clean the electrical contacts on 

the battery and crimping tool. 

3. 

Reinstall the battery and check the tool again. 

 

Problem 

Probable Cause 

Probable Remedy 

Tool is inoperative. 

Dirt, contaminants, etc., in ram 
area of tool. 

Clean tool. 

Crimping tool battery contacts 
damaged. 

Reform contacts. 

Tool components worn or 
damaged. 

Return tool to 

PANDUIT

 Tool Division. 

Dies stop during 
operation. 

Oil level is low. 

Return tool to 

PANDUIT

 Tool Division. 

Air in hydraulic system. 

Pull trigger and hold retract button 
simultaneously.  Hold for approximately 10 
seconds. 

LED glows for 20 
seconds 

Battery charge low. 

Charge or replace battery. 

Tool loses oil. 

Damaged internal seal. 

Return tool to 

PANDUIT

 Tool Division. 

 

DISCONTINUATION OF USE / DISPOSAL  

  The battery cartridge must be specially disposed of according environmental Battery 

Guidelines. 

  For the disposal of the remaining parts, please reference environmental guidelines. 

  Because of possible environmental damage, we recommend disposal of the tool by 

professional companies.  

 

 

ATTENTION:

 

 

Do not dispose of the unit in your 
residential or commercial waste, as it 
would be hazardous to the 
environment.

 

 

 
 

USE OF THE BATTERY CARTRIDGE (CT-2600BC) and 
CHARGING UNIT (CT-2600CHR or CT-2600CHR/E 

The charging unit is run with a nominal voltage of 120 V (CT-2600CHR), or (230 V for 
CT-2600CHR/E) and a frequency of 50-60 Hz.  New batteries must be charged prior to use.  To remove 
the battery, actuate the battery lock and pull it out of the tool.  To charge the battery, connect the power 
plug of the charging unit with the power supply and slide the battery into the charging unit.  The 
charging time is 40 minutes.  The charging level of the battery cartridge can be checked by the right 
LED (multi-color) of the charging unit. 

Summary of Contents for BlackFin CT-2600 Series

Page 1: ...RATION 7 MAINTENANCE INSPECTION 8 Die Closure Inspection 9 Storage and Transport 10 TROUBLESHOOTING 10 DISCONTINUATION OF USE DISPOSAL 10 USE OF THE BATTERY CARTRIDGE AND CHARGING UNIT 10 Terminations...

Page 2: ...taken as a license to operate under or a recommendation to infringe any existing patents This supersedes and voids all previous literature etc Safety Safety is essential in the use and maintenance of...

Page 3: ...d cause serious injury or property damage WARNING Pinch points Keep hands away from the crimping head when crimping Failure to observe this warning could result in severe injury or death WARNING An in...

Page 4: ...ouch or tool box with conductive objects Conductive objects may create a short circuit and damage the battery Do not place a battery on moist ground or grass Moisture may create a short circuit and da...

Page 5: ...akita Battery Charger Part No DC1804 Output 7 2 V 18 0 Volt DC Input 120 Volt AC 50 60Hz Makita Battery Charger for EU Part No DC1804F Output 7 2 V 18 0 Volt DC Input 240 Volt AC 50 60Hz NOTE The CT 2...

Page 6: ...er access to tight corners and other constrained working areas the crimping head may be rotated by hand 360 relative to the tool body The tool is lightweight and provides good handling characteristics...

Page 7: ...THE HIGHEST QUALITY CRIMPING WHEN USED WITH PANDUIT TERMINALS CONNECTIONS UTILIZING THIS TOOL ARE LISTED PER U L 486A AND C S A CERTIFIED ONLY WHEN PANDUIT TERMINALS ARE USED USE OF ANY OTHER BRAND O...

Page 8: ...r inspection and preventive maintenance 20 sec glowing and flashing intermittently After crimp Battery discharged Time for inspection and preventive maintenance Preparing Wire and Positioning Terminal...

Page 9: ...ng the ram retract button in the direction of the battery the dies can be retracted in case of an error or emergency The terminal can first be pre clamped This allows the operator to adjust the positi...

Page 10: ...conditions are met the tool is dimensionally correct F If the above procedure fails to satisfy all GO and NO GO conditions contact your local PANDUIT Sales Office Fig 5 Fig 6 CRIMP DIE JAW CLOSURE DI...

Page 11: ...Hold for approximately 10 seconds LED glows for 20 seconds Battery charge low Charge or replace battery Tool loses oil Damaged internal seal Return tool to PANDUIT Tool Division DISCONTINUATION OF US...

Page 12: ...If charging a battery which has recently been used or which has been exposed to sun for a long period of time T 149 F T 65 C the right LED may flash red In this case remove battery out of charger The...

Reviews: