ACE02 Electronic Swinghandle with PROX Card
Reader Operating Instructions
visit
www.panduit.com
for latest version of this document
Page 3 of 4
Electronically Released
The electronic lock slide is in the unlocked position and the handle can be
pulled open.
•
The Status LED will alternate flashing blue/magenta.
•
The electronic lock status output is 0V while the lock slide is in
the unlocked position.
•
The mechanical lock status output is at its open collector state.
“Electronically Released” State
Mechanically Released
The latch is released by opening the handle or moving the cam from its
lock position.
•
The Status LED will flash blue.
•
The electronic lock status output will be at its open collector state
if the electronic lock slide is in the locked position. It will be 0V if
the lock slide is in the unlocked position.
•
The mechanical lock status output is 0V.
NOTE:
The lock sensor is an optical device that senses the presence
of the lock pawl. Reflectivity of the lock pawl material can affect sensing.
Use only approved locks.
“Mechanically Released” State
Handle not Fully Closed
This is an interim state and may occur while closing the handle when the
cam is not secured by the electronic lock slide. The latch is not fully
secured during this state.
•
The Status LED will alternate flashing blue/red if the cam is not
detected. It will flash blue/red/red if the cam is detected, but the
lock plate is not in the right position. This could be due to
mechanical failure or tampering.
•
The electronic lock status output is 0V if the lock slide is in the
unlocked position. It will be at its open collector state if it is in the
lock position.
•
The mechanical lock status output is 0V if the cam is not
detected. It will be at its open collector state if it is detected.
“Handle not Fully Closed” State
Electronic Lock Slide Error
The electronic lock slide does not respond to the command input signal.
•
The Status LED will flash magenta if the latch is secured. It will
alternate flashing red/magenta if the latch is mechanically
released.
•
The electronic lock status output is at its open collector state.
•
The mechanical lock status output will be at its open collector
state if the cam is in its lock position. It will be 0V if the
mechanical key is moved from its lock position.
Error Input Command Sequence
The ACE02 can accept an input command from an external controller to
flash the status LED red three times. This feature can be used to indicate
that an error event has occurred (e.g. unauthorized access attempt).
The control input signal needs to meet the timing requirements shown
below to flash the status LED red.
T
on
= 5ms
T
on
T
off
= 5ms
T
off
T
burst
T
burst
= 400ms (min)
control
input
electronic
lock slide in
unlocked
position
handle
secured in
housing, cam
in locked
position
electronic
lock slide in
unlocked
position
electronic
lock slide in
locked
position
lock plug in
unlocked
position
cam
detected by
latch
cam not
detected by
latch