5. Operation
Before starting the power unit, check all fluid levels. Add fuel, motor oil and hydraulic oil as required.
The two sections of this power unit must be connected together by the associated hoses and interlocked
prior to starting this modualr power unit.
The hydraulic lines that connect the power unit engine to the reservoir must be connected and the frames
interlocked prior to starting the unit.
To start the power unit, check to make sure the hydraulic control valve is in the “OFF” position.
•
Turn fuel shut-OFF valve to on position.
•
Start engine as follows: cold engine: place throttle control midway between slow and fast positions. Place
choke control into on position. Warm engine: place throttle control midway between slow and fast positions.
Return choke to OFF position as soon as engine starts. A warm engine usually does not require choke on.
•
Retractable start: slowly pull starter handle until just past compression-stop! Return starter handle; firmly pull
straight out to avoid excessive rope wear from starter rope guide.
•
Gradually return choke control to OFF position after engine starts and warms up. Engine/equipment may be
operated during warm up period, but it may be necessary to leave choke partially on until engine warms up.
•
Connection to the power unit: turn control knob to "OFF" position before attaching or disconnecting any
transmission hoses to the power unit or tools. Turn control knob to "on" position to operate attached tools.
• To turn OFF engine, turn the fuel shut OFF valve to OFF position.
WARNING!
•
Carbon monoxide can cause severe nausea, fainting or death. Avoid
inhaling exhaust fumes. Engine exhaust gases contain poisonous carbon
monoxide. Carbon monoxide is odorless, colorless, and can cause death
if inhaled.
NOTE!
•
Choke position for starting may vary depending upon temperature and other
factors. Once engine is running and warm, turn choke to OFF position.
NOTE!
•
Extend starter cord periodically to check its condition. If cord is frayed have
it replaced immediately.
8 av 24
OPERATION AND MAINTENANCE MANUAL I ENG_OMM_MODULAR_POWER_UNIT_RM_P01 I 21th February 2022
@Pandrol 2021