Pando GRUPO PRO Series Installation Manual Download Page 16

INOXPAN S.L.                                                                                                                    

       

 

                                                                        

 

 

VERY IMPORTANT! 

 

DO NOT REMOVE THE PROTECTIVE PLASTIC FROM THE HOOD UNTIL IT IS COMPLETELY 
INSTALLED, IF THIS PLASTIC IS NOT PRESENT IN AREAS THAT COULD HAVE A RISK OF 
DAMAGE  DURING  INSTALLATION,  IT  IS  RECOMMENDED  TO  APPLY  PROTECTIVE 
MATERIALS AGAINST IMPACT, SCRATCHES AND CONTACT WITH CORROSIVE AGENTS. 

 

TAKE  ESPECIAL  CARE  DURING  THE  INSTALLATION  IF  OTHER  WORK  IS  ALSO  IN 
PROGRESS,  BECAUSE  PAINT,  SILICON,  PLASTER  AND  OTHER  MATERIALS  COULD 
CONTAIN CORROSIVE CHEMICALS THAT MAY DAMAGE THE PRODUCT, IN THESE CASES 
IT  IS  RECOMMENDED  TO  ADEQUATELY  PROTECT  THE  HOOD,  BY  FOR  EXAMPLE, 
HERMETICALLY COVERING AREAS THAT COULD BE AFFECTED WITH PLASTIC. 

 

THIS  WILL  AVOID  DAMAGE  TO  THE  OUTSIDE  OF  THE  APPLIANCE,  SOMETHING  THAT 
WILL NOT BE COVERED BY THE GUARANTEE. 

 

 

 

- If the hood is to be used at the same time as gas fuelled or other fuelled appliances 
(not applicable to appliances exclusively designed to blow air into the room) the room 
must be properly   ventilated. 
 
- The exhausted air must not be led through a conduit that is used for exhausting fumes 
from  other  appliances  using  gas  or  other  fuels  (not  applicable  to  devices  destined 
exclusively to discharge the air inside the room). 
 
-The minimum distance between the surface of the cooktop and the lower edge of the 
hood must be 65 cm if the the 

extractor hood 

is fitted over gas cooker. If the installation 

instructions of the gas cooker indicates a greater distance, this must be  followed. 
 
- Regulations regarding air evacuation must be respected. 
 
-  If  the  hood  does  not  have  a 

power  cable  with 

a  plug,  or  other  means  for 

disconnection  from  the  mains,  with  a  separation  of  all  poles  to  ensure  total 
disconnection under category III conditions of overvoltage, means for disconnection of 
the fixed installation must be incorporated in accordance with installation regulations. 
 

 

 EN - SAFETY INSTRUCTIONS 

EN - 

RECOMMENDATIONS TO BEAR IN MIND BEFORE INSTALLATION.   

 

Summary of Contents for GRUPO PRO Series

Page 1: ...Manual de instala o FR Manuel d installation EN Installation Manual Certificado de Empresa de Gesti n de la Calidad UNE EN ISO 9001 2015 The International Certification Network Quality Management Sys...

Page 2: ......

Page 3: ...n su campana le recomendamos que lea atentamente estas instrucciones de utilizaci n en su totalidad y las conserve para posibles consultas posteriores Antes de iniciar la instalaci n leer detenidament...

Page 4: ...se aplica a aparatos destinados exclusivamente para descargar el aire en el interior de la habitaci n El aire evacuado no debe ser enviado por conductos que se utilicen para evacuar los humos de apar...

Page 5: ...reglamentaciones vigentes de instalaci n el ctrica Se ha de tener especial cuidado de d nde se perfora en pared o techos que no hayan l neas ocultas el ctricas tuber as vigas de hierro etc pues ello p...

Page 6: ...ista o compa a el ctrica para que solucionen el problema de suministro el ctrico Para evitar riesgos est prohibida la manipulaci n del aparato Si el cable de alimentaci n est da ado debe ser sustituid...

Page 7: ...r Para que conhe a bem o seu exaustor recomendamos que leia atentamente estas instru es de utiliza o na ntegra e as guarde para poss veis consultas futuras Antes de iniciar a instala o leia atentament...

Page 8: ...o da corrente el trica com uma separa o de contacto em todos os polos que permita um corte total sob as condi es de categoria III de sobretens o deve incluir meios de desconex o da instala o fixa em c...

Page 9: ...x o el trica de acordo com as regulamenta es em vigor Deve ter se especial aten o aos locais de perfura o de paredes ou tetos para n o existir o risco de perfurar linhas el tricas ocultas tubos vigas...

Page 10: ...ntacte um eletricista ou a companhia de eletricidade para que solucionem o problema de fornecimento el trico Para evitar riscos proibida a manipula o do aparelho Se o cabo de alimenta o estiver danifi...

Page 11: ...conna tre votre hotte nous vous recommandons de bien lire ces instructions d utilisation en entier et de bien les conserver pour d ventuelles futures consultations Avant de commencer l installation d...

Page 12: ...avec une s paration des contacts tous les p les assurant une d connexion totale dans des conditions de surtension de cat gorie III ils doivent tre incorpor s des moyens de d connexion incorpor s l ins...

Page 13: ...ementations en vigueur en mati re d installation lectrique Il faut tre particuli rement prudent lorsque l on fore les murs ou le plafond qu il n y ait pas de lignes lectriques dissimul es de tuyaux de...

Page 14: ...er un lectricien ou la compagnie lectrique pour r soudre le probl me d alimentation lectrique La manipulation de l appareil est interdite afin d viter les risques Si le c ble d alimentation est d fect...

Page 15: ...everything about your hood we recommend you read these instructions carefully from beginning to end and keep them for future reference Before starting the installation process read with care this ins...

Page 16: ...ot applicable to appliances exclusively designed to blow air into the room the room must be properly ventilated The exhausted air must not be led through a conduit that is used for exhausting fumes fr...

Page 17: ...electrical disconnection compliant with electrical installation regulations must be fitted Take special care when perforating walls or ceilings and ensure that there are no hidden electrical cables pi...

Page 18: ...rician or your electrical company to solve the problem To avoid hazards it is forbidden to manipulate the appliance If the power cable is damaged it must be replaced by the manufacturer through an aut...

Page 19: ...nterven o adequadamente FR Il doit tre pris en compte et pr voir que la hotte et les p riph riques doivent avoir un acc s facile et s r aux t ches de maintenance ou de r paration du service technique...

Page 20: ...nterven o adequadamente FR Il doit tre pris en compte et pr voir que la hotte et les p riph riques doivent avoir un acc s facile et s r aux t ches de maintenance ou de r paration du service technique...

Page 21: ...CONTENIDO CONTE DO CONTENU CONTENT 150x0 5 mts x1 x1 N CESSAIRES TOOLS NEEDLE HERRAMIENTAS NECESARIAS FERRAMENTAS NECESS RIAS LES OUTILS 3x20 x6...

Page 22: ...REP RES DIMENSIONS 260 496 841 976 520 865 1000 290 160 354 150 501 846 981 265 ENCASTRE INSIRA ENCASTREMENT INSERT IND 55 65 cm GAS 65 cm DISTANCIA A ENCIMERA DIST NCIA PLACA DISTANCE DE LA HOB DIST...

Page 23: ...1 2 INSTALACI N INSTALA O INSTALLATION INSTALLATION A B 3...

Page 24: ...5 INSTALACI N INSTALA O INSTALLATION INSTALLATION PUSH PUSH 6 DESCONECTAR LED...

Page 25: ...7 MUEBLE CABINET INSTALACI N INSTALA O INSTALLATION INSTALLATION...

Page 26: ...8 INSTALACI N INSTALA O INSTALLATION INSTALLATION C X6...

Page 27: ...9 10 INSTALACI N INSTALA O INSTALLATION INSTALLATION CONNECT LED...

Page 28: ...11 INSTALACI N INSTALA O INSTALLATION INSTALLATION 12...

Page 29: ...13 150 INSTALACI N INSTALA O INSTALLATION INSTALLATION...

Page 30: ...CAMBIO POSICION MOTOR POSI O DO MOTOR CHANGER POSITION DU MOTEUR CHANGE ENGINE POSITION 1 2...

Page 31: ...3 4 CAMBIO POSICION MOTOR POSI O DO MOTOR CHANGER POSITION DU MOTEUR CHANGE ENGINE POSITION 180 90...

Page 32: ...CAMBIO POSICION MOTOR POSI O DO MOTOR CHANGER POSITION DU MOTEUR CHANGE ENGINE POSITION 5 6...

Page 33: ...MANTENIMIENTO MANUTEN O MAINTENANCE MAINTENANCE FILTRO PROFESIONAL INOX FILTRO PROFESIONAL INOX FILTRE PROFESSIONNEL INOX PROFESSIONAL FILTER INOX FILTRO FCLR FILTRO FCLR FILTRE FCLR FCLR FILTER...

Page 34: ...1 MANTENIMIENTO MANUTEN O MAINTENANCE MAINTENANCE 2 FILTRO FCLR FILTRO FCLR FILTRE FCLR FCLR FILTER FILTRO FCLR FILTRO FCLR FILTRE FCLR FCLR FILTER...

Page 35: ...s causados por manipula o indevida a l mpadas LED por pessoal n o autorizado ATTENTION Les lampes LED impliquent une manipulation complexe en plus d une connexion d air impliquant un risque de connect...

Page 36: ...2 3 PUSH PUSH MANTENIMIENTO MANUTEN O MAINTENANCE MAINTENANCE...

Page 37: ...2 Long 640mm P 12 W T 4200 K A 24VDC MANTENIMIENTO MANUTEN O MAINTENANCE MAINTENANCE...

Page 38: ...MANTENIMIENTO MANUTEN O MAINTENANCE MAINTENANCE BANDEJA RECOGIDA ACEITE BANDEJA DE COLETE DE LEO TIROIR COLLECTE HUILE OIL COLLECTION TRAY 1 2 A B 3...

Page 39: ...INOXPAN S L NOTAS NOTAS REMARQUES NOTES...

Page 40: ...INOXPAN S L NOTAS NOTAS REMARQUES NOTES...

Page 41: ...INOXPAN S L NOTAS NOTAS REMARQUES NOTES...

Page 42: ...INOXPAN S L...

Page 43: ......

Page 44: ...lona Spain Tel 34 93 757 94 11 Fax 34 93 757 96 53 www pando es com pando pando es Export export pando es Tel 902 41 55 11 Certificado de Empresa de Gesti n de la Calidad UNE EN ISO 9001 2015 The Inte...

Reviews: