32 | EN
Installation instructions
In Canada:
Wiring must conform to Canadian Electrical
Code C22.1- latest edition. You can obtain a
copy of the Canadian Electrical Code by
writing to: Canadian Standards Association
178 Rexdale Boulevard Rexdale (Toronto),
Ontario, Canada M9W 1R3
4. Wire size (Copper or Aluminum wire) and
connections must be suitable for the rating of
the appliance as per the National Electrical
Code requirements. The flexible armoured
cable extending from the oven should be
connected directly to the junction box.
5. The junction box should be located so as to
allow as much slack as possible between the
junction box and the oven so it can be
moved if servicing is ever required.
6. A U.L. listed conduit connector must be
provided at each end of the power supply
cable.
Electrical connections
Be sure your appliance is properly installed
and grounded by a qualified technician. Ask
your dealer to recommend a qualified
technician or an authorized repair service.
This appliance is manufactured with a green
GROUND wire connected to the oven chassis.
After making sure that the power has been turned
off, connect the flexible conduit from the oven to
the junction box using a U.L. listed conduit
connector. The figures and the instructions
provided below present the most common way of
connecting the ovens.
Your local codes and ordinances, of course, take
precedence over these instructions.
WARNING” Risk of Electric Shock, frame
grounded to neutral of appliance through a
link.
Grounding through the neutral conductor is
prohibited for new branch-circuit installations
(1996 NEC); mobile homes; and recreational
vehicles, or in an area where local codes prohibit
grounding through the neutral conductor. For
installations where grounding through the neutral
conductor is prohibited:
•
Disconnect the ground from the neutral at
free end of conduit;
•
Use grounding terminal or lead to ground
unit; and
•
Connect neutral terminal or lead to branch
circuit neutral in usual manner.
3-Wire branch circuit (for US only)
Refer to the following Figure, where local codes
allow the connection of GROUND wire from the
oven to the branch circuit NEUTRAL wire (gray or
white colored wire):
•
If local codes permit, connect the green
GROUND wire from the oven and the white
wire from the oven to the branch circuit
NEUTRAL wire (gray or white colored wire).
•
Connect the red and black leads from the
oven to the corresponding leads in the
junction box.