background image

English

 

 

6.

 

General Specifications 

Display 

PAN MV-690A: LED 
PAN MV-690B:  3 ½ Digits LCD Display, 
bargraph, Backlight  

Rotary field indication 

100 

 400 V (50/60 Hz) 

Category 

CAT III  690 V 

Overload protection 

PAN MV-690A: 400 V (AC/DC) or 690 V (DC) 
PAN MV-690B:  690 V (AC/DC) 

Maximum value (MAX) 

< 0,2 A (1s);  < 3,5 mA (5s) 

Test current 

5 μA

 (Continuity test) 

Internal impedance 

 

1MΩ

 

Response time 

< 0,1s 

Measuring rate 

2-3x /s 

Max. uptime 

to 230 V   5 s 
to 690 V   3 s 

Power consumption 

250 mW 

Power supply 

2 x 1,5 V (AAA) Battery(s) 

Operating temperatute 

-10º C to 55º C / < 85% Relative Humidity 
(%RH) 

Altitude 

max. 2.000 m 

Weight 

PAN MV-690A:     204 g 
PAN MV-690B:     216 g 

Dimensions 

240 x 78 x 40mm 

 
 

 

 

Summary of Contents for PAN MV-690A

Page 1: ...English 1 MANUAL PAN MV 690A PAN MV 690B...

Page 2: ...with LED Display LCD Display Contents 1 Introduction 3 2 Scope of delivery 3 3 Safety Instructions 4 4 Symbols Description 5 5 Panel Description 6 6 General Specifications 9 7 Operating Instructions...

Page 3: ...read this operating manual carefully before using the device to become familiar with the proper handling of the device and to prevent faulty operations Please follow all the safety instructions Nonobs...

Page 4: ...therwise it may be damaged Never ground yourself while making electrical measurements Do not touch any exposed metal pipes fittings etc which could have a ground potential Ensure that your body is iso...

Page 5: ...domestic waste at the end of its service life but should be handed over at a collection point for recycling electrical and electronic devices CAT III The device is designed for making measurements in...

Page 6: ...English 6 5 Panel Description MV 690 A...

Page 7: ...English 7 MV 690 B...

Page 8: ...V 690 B 5 Indicator of the live phase 6 LED Voltage testing with reduced impedance only PAN MV 690A 7 Rotating field counter clockwise 8 Rotating field clockwise 9 Display Continuity test 10 Test butt...

Page 9: ...C or 690 V DC PAN MV 690B 690 V AC DC Maximum value MAX 0 2 A 1s 3 5 mA 5s Test current 5 A Continuity test Internal impedance 1M Response time 0 1s Measuring rate 2 3x s Max uptime to 230 V 5 s to 69...

Page 10: ...h 10 Function Range Accuracy of the value displayed in DC voltage V 12 V 30 to 0 24 V 36 V 50 V 120 V 230 V 400 V 690 V AC voltage V 50 60Hz 12 V 30 to 0 24 V 36 V 50 V 120 V 230 V 400 V 690 V only MV...

Page 11: ...azardous voltage The probes may not be long enough to touch the hot parts in some 230V wall sockets as they are deep inside As a result the reading can show 0 volts Make sure that the probes touch the...

Page 12: ...ormed when functional batteries are inserted 1 Touch a conductor with the device probe 2 A beep indicates that the conductor is under voltage Testing of an residual current circuit breaker 1 Touch pro...

Page 13: ...a resistor 35 you hear a beep When the circuit is open the display shows OL Rotation indicator of rotating fields The tester can show the direction of the rotary field of three phase The rotation ind...

Page 14: ...ltage sources before opening the device 1 Open the battery compartment 12 2 Replace the battery Mind the correct polarity 3 Replace the battery compartment lid and secure the screw 4 Disposal of the f...

Page 15: ...ding to purchase receipt Further information on complaint handling can be found at www pancontrol at complaints In case of spare part requirement or in case of queries or problems please get in touch...

Reviews: