Settings
OMCTT5621E18
34
8.1.5 Memory deletion
If you would like to delete any welding conditions that you
programmed, follow the below steps.
Operation
Set-value display
LCD display
1
Hold down the JOG dial, and while holding it down,
turn on the “POWRE” switch.
Then indication changes to
2
Turn the JOG dial until the screen on the right
appears.
3
Press the JOG dial.
4
Press the JOG dial.
Note
The screen on the right
appears on the digital
ammeter.
5
Turn the JOG dial to select a program number you
want to delete.
* Stored program numbers appear in series.
(When selecting “P01”)
6
Press the JOG dial.
7
Turn the JOG dial and have “YES” displayed.
8
Press the JOG dial.
* To continue to delete the memories of other pro
-
gram numbers: Go to no (4).
9
On completion of the desired deletion of program number memories, turn the power switch off.
Rescue Menu
YC-300B Series
1
Set Defaults?
No
2
Delete Page
P - -
2 Delete Page
P -
-
Are you sure?
* * *
*
2 Delete Page
P -
-