14
■
Connection with a Time Lapse VCR
Alarm in/out and recover-reset in/out are connected between the time lapse VCR and the rear of the controller.
Note:
Use a relay as shown below when connecting an indicator such as a buzzer that exceeds 16 V DC 100 mA.
ALARM IN
1
2
G
3
4
Relay
+12 V
NC NO
Alarm Indicator etc.
Time Lapse VCR
1 ALARM IN
2 ALARM OUT
G GROUND
3 RECOVER IN
4 RESET OUT
NC: Normally Closed Contact
NO: Normally Open Contact
2
4
ALARM
IN
1
COM
2
ALARM
RESET IN
3
ALARM
RECOVER OUT
4
ALARM
OUT
5
1
3
5
■
Cable-loss Compensation Setting
The maximum allowable cable length between a camera and a controller is 900 m (3 000 ft) when using an RG-59U BELDEN
or equivalent cable. Cable loss compensation can be adjusted in the setup menu as S, M or L.
Camera
WV-CU161C
A m (A ft)
0 (0)
≤
A < 400 m (1 300 ft)
→
S
400 (1 300)
≤
A < 700 m (2 300 ft)
→
M
700 (2 300)
≤
A < 900 m (3 000 ft)
→
L
Cable compensation
parameter in WV-CU161C
Setup menu
Cable length (with RG-59U
BELDEN 9259 or equivalent)
Unit: m (ft)