background image

Installation

Step2 Fixing the brackets

Step1 Preparations

The installation tasks are explained using 4 steps.

There are 4 methods to install the camera to a ceiling or wall as described below. Prepare the 

required parts for each installation method before starting the installation. The following are the 

requirements for the various installation methods.

Installation method

Recommended 

screw

Minimum pull-out 

strength

[1]

 Mount the camera on the two-gang junction 

box using the 

A

 attachment plate (accessory).

 M4 screws x 4

196 N {44 lbf}/1 pc.

[2]

 Directly mount the camera onto the ceiling or 

wall using the attachment plate (when wiring 

can be installed in the ceiling or wall).

 M4 screws x 4

196 N {44 lbf}/1 pc.

[3]

 Mount the camera onto the ceiling or wall using 

the 

B

 base bracket (accessory) (when conduits 

are used for wiring, or when there is no space 

available for wiring in the ceiling or the wall).

*1

 M4 screws x 4

196 N {44 lbf}/1 pc.

[4] 

When installing on a ceiling using the 

WV-Q121B (ceiling hanging mount bracket) 

and WV-Q124 (suspension mount bracket).

*1*2

M10 screws x 4

1411 N {317 lbf}/1 pc.

[5]

 When installing on a wall and pole using the 

WV-Q122A (wall mount bracket) and WV-Q124 

(mount bracket)

*1 *3

M10 screws x 4

823 N {185 lbf}/1 pc.

*1  Use 4 screws (M4 x 8 mm, accessory) to fix the 

A

 attachment plate (accessory) to the 

B

 base bracket (accessory) or WV-Q124.

*2  For information on the procedure for attaching the WV-Q121B and WV-Q122A with the 

WV-Q124, refer to the operating instructions included with the respective attachment brackets.

*3  For information on the procedure for attaching the WV-Q122A with the WV-Q124, refer to 

the operating instructions included with the respective attachment brackets.

IMPORTANT:

 

Procure 4 screws (M4) to secure the 

A

 attachment plate (accessory) or 

B

 base 

bracket (accessory) to a ceiling or a wall.

 

When mounting the camera on a concrete ceiling, use an AY plug bolt (M4) for 

securing. (Recommended tightening torque: 1.6 N·m {1.18 lbf·ft})

 

Select screws according to the material of the ceiling or wall that the camera will be 

mounted to. In this case, wood screws and nails should not be used.

 

If a ceiling board such as plaster board is too weak to support the total weight, the 

area shall be sufficiently reinforced.

[1] Using a two-gang junction box

[2]  Directly mount the camera to the ceiling or wall using the attachment plate

[3] Mount the camera to a ceiling or a wall using base bracket

<Wiring using a ceiling or wall conduit>

The 

B

 base bracket (accessory) can be fixed in any of the following 6 screwing positions 

according to ceiling and wall conditions. Match the hole used when installing the camera to 
any of positions A to F.

<Mounting the base bracket>

<Making holes and wiring from the back side of a ceiling or wall>

*  When making holes and wiring from 

a ceiling or wall, do not remove the 
cap for the female thread for the 
conduit.

A

 Remove the cap for the female thread for the 

conduit by using a hexagon wrench (ISO 2936, 

width across flats S=5 mm {3/16 inches}).

The female thread for conduit is compliant with 
ANSI NPSM (parallel pipe threads) 3/4 inches or 
G3/4 of ISO 228-1.

Attach the base bracket and attachment 

plate to a ceiling or wall.

*3 The wiring hole diameter is 25.4 mm {1 inch}. Select any of the 2 base bracket fixture holes 

of 

E

 template B (for the base bracket, accessory) when installing the base bracket.

*4 When attaching the base bracket to a one-gang junction box in Position E, secure the base 

bracket with 2 screws (M4, 

locally procured

).

IMPORTANT:

 

If open wiring is conducted, be sure to use conduits and run the cables inside the tubes to 
protect the cables from direct sunlight.

 

Installation work shall be such that there is no exposure to water into the architecture 
through the conduits having been joined.

Step1

Make sure all items are prepared 

before beginning installation.

Step2

Mount the brackets to a ceiling or 

wall

Step3

Connect cables, and then attach the 

camera to the mount bracket.

Step4

Adjust the direction of the image.

Cap for the female 
thread for the 
conduit

Step3 Mount the camera to the attachment plate

Step4 Adjustment

A

 Check the position of attachment 

mounting screws on the bottom side 

of the camera.

B

 Connect cables to the camera according to the 

instructions in “Making connections”, and mount the 

camera by inserting the attachment mounting screws 

into the holes of the 

A

 attachment plate (accessory).

Loosen 2 sub cover fixing screws using 

the 

G

 bit (accessory).

D

 Remove the sub cover from the camera, 

and secure the camera using camera fixing 

screws. (Recommended tightening torque: 

0.78 N·m {0.58 lbf·ft})

Note:

 

After the cables have been connected to the camera, align the direction of the Panasonic logo 

on the camera with “ TOP” of the 

A

 attachment plate (accessory). Align the OPEN mark of 

the enclosure side panel with the protruding part of the 

B

 base bracket (accessory), insert

3 attachment mounting screws into the attachment plate, rotate the camera approximately 15°, and 

move the LOCK mark to the protruding part of the base bracket to temporarily secure the camera. 

(When directly attaching the attachment plate to a ceiling or wall, align the OPEN mark to the 

hook part of the attachment plate.) 

IMPORTANT:

 

Be sure to tighten the camera fixing 

screw. Failure to observe this may 

cause camera trouble due to camera 

falling. (Recommended tightening 

torque: 0.78 N·m {0.58 lbf·ft})

A

 Loosen the SD memory card slot cover fixing 

screw on the side of the camera using the 

G

 bit (accessory), and open the SD memory 

card slot cover.

B

 Turn on the camera. The LINK indicator 

inside the SD memory card slot cover lights. 

Make sure that the ACT indicator is blinking. 

(Refer to the descriptions in “Major operat-

ing controls” for more information about the 

indicators.)

C

 Perform camera settings while referring to the 

included “Configure the settings of the cam

-

era” (leaflet), and check if camera images are 

displayed on the PC monitor.

Rotate the image rotation gear using the 

included bit, and align the upwards direction 

of the image as necessary.

Rotating the image rotation gear clockwise 

also rotates the PC image clockwise. Rotating 

the image rotation gear counterclockwise also 

rotates the PC image counterclockwise.
Adjustable range of the PC image: 

          -45° to +45°

 

To remove the SD memory card, hold 

down the SD ON/OFF button for about  

2 seconds. When the SD MOUNT indicator 

goes out, you can remove the SD memory 

card.

 

After the SD memory card has been 

replaced, press the SD ON/OFF button, 

and make sure the SD MOUNT indicator 

is continually lit.

 

If you do not press the SD ON/OFF 

button after replacing the SD memory 

card, the SD MOUNT indicator is 

continually lit approximately 5 minutes 

later.

D

 Remove the cover film from the dome cover 

surface.

E

 Align the upwards direction of the image 

while rotating the image rotation gear and 

checking the image on the PC monitor.

Insert an SD memory card into the slot, if 

necessary.

Close the SD memory card slot cover, 

and tighten the SD memory slot cover slot 

cover fixing screw to secure the cover.

 

(Recommended tightening torque: 

0.78 N·m {0.58 lbf·ft})

H

 Return the sub cover to its original position 

and secure it using 2 sub cover fixing 

screws. (Recommended tightening torque: 

0.78 N·m {0.58 lbf·ft})

IMPORTANT:

 

Ensure that the SD memory card slot 

cover’s fixing screw is firmly secured. 

Failure to observe this may cause elec-

tric shock or malfunction.

 

Securely tighten the 2 sub cover fixing 

screws. Failure to do so may cause the 

camera to drop.

 

After the installation is completed, clean 

the dome cover surface with a soft 

cloth, etc.

 

After the installation is complete, if the 

image is out of focus, turn off the cam-

era, and then turn it on again. If the 

image is still out of focus, select the 

[Image/Position] tab from 

[Setup]→[Image/Audio], and then re-

adjust the back focus from [Setup>>] of 

[Back focus].

Sub cover fixing screws

Hook part (attachment plate)

Protruding part

Camera fixing screw

Attachment mounting screws

Protruding part

Sub cover

Sub cover

TOP

IMPORTANT:

 

Disconnect the 12 V DC power source and PoE power source to prevent power from being 

supplied during mounting work. 

 

Because the sub cover is attached to the camera with the sub cover sheet, do not remove 

the sub cover.

 

For installations on the wall, to prevent water from accumulating on the surface of the 

dehumidifying device, install the camera so that the dehumidifying device does not face up. 

If water accumulates on the surface of the dehumidifying device, it cannot function properly.

SD memory card 

slot cover

SD memory card 
slot cover

SD memory card 
slot cover

SD memory card slot cover
fixing screw

SD memory card

SD memory card slot 
cover fixing screw

Image rotation gear

Sub cover fixing screws

Sub cover

Image rotation 
gear

G

 

 Bit 

(accessory)

*  When removing the camera, perform 

removal by following the installation pro-

cedure in the reverse order.

 

Insert the SD memory card with its label 

facing down.

 

Mount the 

B

 base bracket 

(accessory) to a ceiling or wall 

using 4 fixing screws (M4, 

locally procured). Refer to the 

installation example on the 

right and pass the wiring 

through the base bracket.

 

Secure 

A

 attachment plate 

(accessory) to base bracket 

using 4 

C

 attachment fixing 

screws (accessory).

(Recommended tightening 

torque: 0.78 N·m {0.58 lbf·ft})

 

Mount the 

B

 base bracket 

(accessory) to a ceiling or wall 

using 4 fixing screws (M4, locally 

procured). Refer to the installation 

example on the right and pass the 

wiring through the base bracket.

 

Secure 

A

 attachment plate 

(accessory) to base bracket using 

C

 attachment fixing screws 

(accessory). (Recommended 

tightening torque: 0.78 N·m 

{0.58 lbf·ft})

85 mm {3-11/32 inches}
(85.7 mm {3-3/8 inches})

ø

25.4 mm 

{

ø

1 inch}

*3

85 mm 
{3-11/32 inches}
(85.7 mm 
{3-3/8 inches})

138 mm 
{5-7/16 inches}

ø

25.4 mm 

{

ø

1 inch}

*3

138 mm 
{5-7/16 inches}

83.5 mm
{3-9/32 inches}

46 mm
{1-13/16 inches}

ø

25.4 mm 

{

ø

1 inch}

*3

63 mm
{2-15/32 inches}

ø

25.4 mm 

{

ø

1 inch}

*3

63 mm
{2-15/32 inches}

83.5 mm
{3-9/32 inches}

ø

25.4 mm 

{

ø

1 inch}

*3

108.5 mm
{4-9/32 inches}

70 mm
{2-3/4 inches}

ø

25.4 mm 

{

ø

1 inch}

*3

Position A

Position D

Position B

Position C

Position E

Position F

*4

TOP

Fixing screws
(4 pcs., locally procured)

Fixing screws (4 pcs., locally procured)

A

  

Attachment 

plate (accessory)

A

  

Attachment plate 

(accessory)

D

  

Template A (for the 

attachment plate, accessory)

Cable access hole
(ø30 mm  
{ø1-3/16 inches})

46 mm 
{1-13/16 inches}

46 mm 
{1-13/16 
inches}

83.5 mm
{3-9/32 
inches}

83.5 mm
{3-9/32 inches}

Two-gang 
junction box

TOP

TOP

TOP

Fixing screws(M4

 x 

4, locally 

procured)
Minimum pull-out strength: 
196 N {44 lbf} (per 1 pc.)

C

  Fixing screws for attachment 
plate: x 4 (accessory) 
(Recommended tightening 
torque: 0.78 N·m {0.58 lbf·ft})

B

 

Base bracket (accessory)

A

 

 Attachment plate

(accessory)

TOP

Conduit

Fixing screws (M4

 x 

4, locally procured)

Minimum pull-out strength:
196 N {44 lbf} (per 1 pc.)

C

  Fixing screws for attachment plate: x 4 (accessory)
(Recommended tightening torque: 0.78 N·m {0.58 lbf·ft})

B

 

 Base bracket 

(accessory)

A

 

 Attachment 

plate 
(accessory)

TOP

*  After turning on the camera, there may be 

a sound produced from the lens for several 

seconds. This is not a malfunction.

* Part of the sub cover is not shown.

* Part of the sub cover is not shown.

WV-Q121B

WV-Q124

Camera

[4]

Note:

 

The direction of “ TOP” on the 

A

 attachment plate (accessory) determines the upwards 

direction of the image on the PC monitor.

 

When mounting on a ceiling, determine the direction that you want images to be dis-

played upwards on the PC monitor, and then mount so that the 

A

 attachment plate 

(accessory) aligns with “ TOP” on 

D

 template A (for the attachment plate, accessory).

 

When installing on a wall, attach the 

A

 attachment plate (accessory) so that “ TOP” 

faces upward.

B

 

Base bracket (accessory)

Note:

 

Make sure to attach the 

A

 attachment plate (accessory) so that the “ TOP” mark faces 

in the opposite direction of the cap for the female thread for the conduit.

 

The direction of “ TOP” on the 

A

 attachment plate (accessory) determines the upwards 

direction of the image on the PC monitor. Determine the direction that you want images to 
be displayed upwards on the PC monitor, and then align the direction of the 

B

 

base 

bracket (accessory).

 

When installing on a wall, attach the 

A

 attachment plate (accessory) so that “ TOP” 

faces upward.

<When attaching the attachment 

  plate directly to a ceiling or wall>

Sub cover sheet

 

The default position of the image rotation 

gear is 0°.

 

When using Double Panorama, if the 

image rotation gear is in its default 

position, images are display at a 45° 

angle. If you want to divide Double 

Panorama images horizontally or 

vertically, adjust the image rotation gear.  

Adjustments to the image rotation gear are 

applied to all image capture modes, 

including Double Panorama.

Note:

 

When Double Panorama or 

Panorama is selected for the image 

capture mode, you can rotate the 

image at 90° intervals by using pre-

set position settings. To make further 

fine adjustments to the image angle, 

adjust the image rotation gear. Refer 

to 11.1 and 11.5.4 of the Operating 

Instructions for more information.

Note:

Take care of the following points when 

using monitor out. 

 

Select “9M Fisheye” or “4M Fisheye” 

for “Image capture mode”.

 

Locally procure the ø3.5 mm monau-

ral mini plug RCA pin jack conver-

sion cable.

 

● Select the [Setup]→[Basic] tab, and 

then select On (NTSC) or On (PAL) 

for [Monitor out].

* This illustration shows the 

  camera after being rotated.

A

 

Attachment plate

    (accessory) holes x 3

WV-Q122A

WV-Q124

Camera

[5]

Reviews: