1-1
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
y
u
i
o
!0
!1
q
!2
r
t
e
w
ON
INT
1 SYNC
2 UPSIDE
DOWN
3 AP GAIN
4 BW
5 BW AUTO
LEVEL
6 LED
LL
OFF
ON
OFF
AUTO
LOW
HIGH
OFF
ON
SHARP SOFT
1
2
3
4
5
6
q
LEFT Button
Moves the cursor to the left and selects items in the CAM SETUP menu.
w
UP Button
Moves the cursor upward and selects items in the CAM SETUP menu.
e
RIGHT Button
Moves the cursor to the right and selects items in the CAM SETUP menu.
r
Set Button
This button is used to activate an item selected in the CAM SETUP menu.
t
DOWN Button
Moves the cursor downward and selects items in the CAM SETUP menu.
y
SYNC switch (SW1)
Switches internal sync (INT) mode or line-lock (LL) mode. The factory default setting is INT.
u
UPSIDE DOWN switch (SW2)
Turn the picture upside down by selecting ON. The factory default setting is OFF.
i
AP GAIN switch (SW3)
Selects the aperture gain level to SHARP or SOFT. The factory setting is SHARP.
o
BW switch (SW4)
Switches to AUTO between colour and black -and-white picture in response to light input. The factory default setting is OFF.
!0
BW AUTO LEVEL switch (SW5)
Selects the illuminance level in LOW or HIGH mode for B/W. The factory default setting is HIGH.
!1
LED ON/OFF switch (SW6)
The factory default setting is ON.
!2
Monitor output Jack (3.5 Diam. Mini jack)
Connects the LCD monitor and such devices with 3.5 mm in diam. 2-pole plug for checking images.