161
SEP 2004
Ver. 1.2
DP-1520P/1820P/1820E
E2- 10 System Console Drive Motor
Rotation
1. Drive Mechanism defective.
2. Drive Motor connector disconnected.
3. Drive Motor defective.
4. CST2 PCB connector disconnected.
5. CST3 PCB connector disconnected.
6. CST3 PCB defective.
7. PS connector disconnected.
8. PS defective.
9. SPC PCB connector disconnected.
10. SPC PCB defective.
E3: Development System Error
Code
Function
Possible Cause(s)
E3- 01 Toner Bottle Motor Rotation
1. Toner Bottle Motor connector disconnected.
2. Toner Bottle Motor defective.
3. Toner Bottle Motor Drive Mechanism defective.
4. Toner Bottle installed incorrectly.
5. SPC PCB connector disconnected.
6. SPC PCB defective.
7. Toner Bottle Home Position Sensor connector
disconnected.
8. Toner Bottle Home Position Sensor defective.
E3- 02 Toner Screw Motor Over
Current
1. Toner Screw Motor defective.
2. Toner Screw Motor Drive Mechanism defective.
3. SPC PCB defective.
E3- 03 Toner Density Sensor Gain
1. Sensor connector disconnected.
2. Sensor defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
E3- 10 High Voltage Power Supply
leak (1) - Grid Charge Voltage
1. PS connector disconnected.
2. PS defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
5. Corona Wire is abnormal. (Check for: contamination
with foreign particles, broken, not installed in the
proper position or loose tension)
E3- 20 Main Motor Rotation
1. Drive Mechanism defective.
2. Main Motor connector disconnected.
3. Main Motor defective.
4. SPC PCB connector disconnected.
5. SPC PCB defective.
6. PS defective.
E2: Lift DC Motor Error
Code
Function
Possible Cause(s)
Summary of Contents for Workio DP-1820P