20
●
Connection with the Uninterruptible Power System (UPS)
This is an example of connection with the uninterruptible power system (UPS) to be installed to protect from a power outage.
When a signal is supplied to the outage detection input terminals from the uninterruptible power system (UPS), internal pro-
cessing (stops recording safely) will be started to shut off the power supply for this unit.
After completing the internal processing, a signal will be supplied from the outage processing end output terminal to the unin-
terruptible power system (UPS). Then, the power supply to this unit can be suspended.
●
Connection of the control output
• When an alarm device such as a buzzer or a lamp is connected, the signal output from Pin Nos. 15 - 18 can be used to
notify the status by sounding a buzzer or lighting a lamp.
• The following example is of a connection with the HDD error output (pin no. 16).
!3
!6
Alarming device
Relay, etc.
(Earth)
(HDD error output)
ALARM/CONTROL
*Install according
to your need
Uninterruptible
power system
(UPS)
This unit
To an AC outlet
!3
@3
!9
(Outage processing completion output)
(Outage detection input)
(Earth)
Power cord
(COM)
(Detection)
(Shutdown)
ALARM/CONTROL
* Refer to the operating
instructions of the used
product for further
information about
connection of the UPS.