POWER

ON

OFF

ALARM

  ALARM
SUSPEND

Data Multiplex Unit WJ-MP204C

Summary of Contents for WJMP204C - DATA MULTIPLEX UNIT

Page 1: ...ct or operate this product please read these instructions carefully and save this manual for future use Model No WJ MP204C Data Multiplex Unit Operating Instructions POWER ON OFF ALARM ALARM SUSPEND Data Multiplex Unit WJ MP204C ...

Page 2: ...VICING TO QUALIFIED SERVICE PERSONNEL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN SA 1965 SA 1966 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment gen...

Page 3: ...your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the app...

Page 4: ...al Setting 17 RS 485 DATA Port Connection PS Data 17 RS 485 Terminal Connection Camera Communication 18 SETUP PROCEDURES 19 Prior to setup 19 Confirmation 19 To open or close the setup menu 19 Buttons used in the setup 19 Setup menus 20 Setup Menus for PS Data 21 Communication setup PS Data 21 System setup PS Data 21 Setup Menus for Camera Communication Protocol 24 Communication setup Camera Commu...

Page 5: ...for use of the PS Data protocol Alarm in out and remote in out switchable Displayed Image on the monitor screen Camera channel selected Alarm channel activated Setup menus Camera control with WV CU360C Pan tilt head and housing control Motorized lens control focus zoom iris etc Camera setup menus Alarm Function Inputs Video Motion Detection by the camera Alarm input to the terminal Output Signal i...

Page 6: ...e with care Do not strike or shake as this may damage the appli ance Do not expose the appliance to water or moisture nor try to operate it in wet areas Do take immediate action if the appliance becomes wet Turn the power off and refer servicing to qualified service personnel Moisture can damage the appliance and also cause electric shock Do not use strong or abrasive detergents when cleaning the ...

Page 7: ...utton confirms the presently selected parameter or opens a submenu t Setup escape button SETUP ESC Holding down this button opens or closes the setup menu In the setup operation pressing this button returns to an upper layer setup menu y Down 1 button C Selects camera 1 in normal operation Moves the cursor downward in the setup operation u Up 2 button D Selects camera 2 in normal operation Moves t...

Page 8: ...the EIA RS 170 standard Do not input signals having a high jitter content such as VCR playback signals 6 VS VD Output Connector VS VD OUT Supplies a sync signal depending on the input to the VS VD IN connector and setting of the MODE DIP switch 1 Refer to page 15 and 23 for details 7 Alarm Remote Terminal ALARM REMOTE Pins 6 9 are used in one out of four ways most suitable to your system requireme...

Page 9: ... rear of each WJ MP204Cs 2 Install the WJ MP204Cs with the rack mounting brackets on the rack using four screws not supplied Cautions Do not block the ventilation opening or slots in the cover to prevent the appliance from overheating Always keep the temperature in the rack within 45 C 113 F Secure the rear of the appliance to the rack by using additional mounting brackets procured locally if the ...

Page 10: ...NAL GND 4 3 2 1 OUT OUT IN OUT 4 3 2 1 Camera Monitor System Controller WV CU360C Video signal RS485 signal Panasonic Security Data mode 1 ch 2 ch 3 ch 4 ch Camera Site Control Site 4 Line Termination ON Panasonic Security Data mode MODE Termination ON Controller No 1 OPERATE LOGIN ALARM CAM SETUP PROGRAM PROGRAM PRESET UNIT A IRIS CLOSE OPEN NEAR FAR WIDE TELE FOCUS ZOOM AUTO FOCUS IRIS RESET AUT...

Page 11: ...ne Termination OFF Panasonic Security Data mode Monitor MODE Panasonic Security Data mode OPERATE LOGIN ALARM CAM SETUP PROGRAM PROGRAM PRESET UNIT A IRIS CLOSE OPEN NEAR FAR WIDE TELE FOCUS ZOOM AUTO FOCUS IRIS RESET AUTO SETUP ALM SUSPEND FUNCTION CAM FUNCTION MULTI SCREEN SELECT DEF WIPER EL ZOOM SHIFT ALM RESET VTR CAM STILL ALM RECALL PATROL LEARN PATROL STOP AUX 1 AUX 2 B W UNIT SEQ PAUSE SL...

Page 12: ...ermination OFF Panasonic Security Data mode Monitor MODE Panasonic Security Data mode OPERATE LOGIN ALARM CAM SETUP PROGRAM PROGRAM PRESET UNIT A IRIS CLOSE OPEN NEAR FAR WIDE TELE FOCUS ZOOM AUTO FOCUS IRIS RESET AUTO SETUP ALM SUSPEND FUNCTION CAM FUNCTION MULTI SCREEN SELECT DEF WIPER EL ZOOM SHIFT ALM RESET VTR CAM STILL ALM RECALL PATROL LEARN PATROL STOP AUX 1 AUX 2 B W UNIT SEQ PAUSE SLOW S...

Page 13: ... 1 HDD 2 HDD 3 HDD 4 Extension Unit WJ HDE OPERATE System Controller POWER ON OFF ALARM Data Multiplex Unit WJ MP204 ALARM SUSPEND POWER ON OFF ALARM Data Multiplex Unit WJ MP204 ALARM SUSPEND System Controller WV CU360C LAN Ethernet 10 Base T or 100 Base TX WJ HDB502 Network Interface Board PS Data WJ MP204C WJ MP204C A Digital Disk Recorder Connection PS Data To connect with ordinary cameras tha...

Page 14: ... RS485 2 3 4 G N D B A G N D B A 1 System Controller WV CU360C Matrix Switcher WJ SX350 Data Multiplex Unit WJ MP204C Data Multiplex Unit WJ MP204C Camera Camera Monitor Unit Address 1 Unit Address 2 Termination ON MODE 2 Line Camera communi cation mode 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 ch Video signal RS485 signal camera site RS485 signal controller site OPERATE LOCK ALARM AUTO IRIS CLOSE OPEN...

Page 15: ...unication chain DIP Switch Setting A 6 bit DIP switch mounted on the rear panel specifies communication mode and sync setup The default position is marked with an asterisk in the table below Bit 1 specifies the setup for synchronization Refer to page 23 VS VD IN and OUT for details Bit 2 is reserved Bit 3 specifies the communication protocol used in the system Bit 4 is reserved Bit 5 specifies the...

Page 16: ... 16 V DC 100 mA maximum after changing an internal switch SW 704 Pin 4 accepts a spot switching pulse input from other units in a multi unit connection A no voltage make contact is accepted Pin 5 supplies a spot switching pulse output to other units when the unit selects a new camera channel in a multi unit connection The output type is a low active open collector with a capacity of 16 V DC 100 mA...

Page 17: ...ot output image to CH 1 Pin 7 accepts the signal to switch image to CH 2 Pin 8 accepts the signal to switch image to CH 3 Pin 9 accepts the signal to switch image to CH 4 8 Spot switching output Available when TERMINAL is set to REMOTE in the setup and the internal connector is changed to CN702 ALM OUT Pin 6 supplies a tally output while CH 1 is selected Pin 7 supplies a tally output while CH 2 is...

Page 18: ...s 8 Internal Diagram 8 4 line Full Duplex 8 2 line Half Duplex DATA Data Multiplex Unit WJ MP204C System Controller WV CU360C DATA RS 485 Cable Termination ON Termination ON DATA Data Multiplex Unit WJ MP204C Branch Cable Termination OFF Termination ON System Controller WV CU360C DATA DATA Video Multiplexer WJ FS309 WJ FS316 RS 485 Cable Termination ON RS 485 Cable RA TB 4 3 2 1 TA RB WJ MP204C SY...

Page 19: ...the front panel buttons on the WJ MP204C are used Check below which WJ MP204C front panel buttons are equivalent to the buttons on the WV CU360C Data Multiplex Unit WJ MP204C C button Moves the cursor downward D Moves the cursor upward Decreases the parameter value Increases the parameter value SET Validates the selected parameter or opens a sub menu when appears ESC Returns the menu to a higher l...

Page 20: ...D RATE DATA BIT PARITY CHECK STOP BIT WAIT TIME SYSTEM ALARM MODE MONITOR SPOT MONITOR SPOT ALARM DISPLAY SITE ALARM TERM ALARM ALARM OUTPUT ALARM DATA COMP VD2 DATA CAMERA IN COMP VD2 DATA VS VD INPUT CAMERA CONFIG CAMERA CONFIG DAISY MODE TERMINAL Setup menus for PS Data COMMUNICATION CAM ADDRESS CAM ADDRESS BAUD RATE DATA BIT PARITY CHECK STOP BIT WAIT TIME DELAY TIME XON XOFF SYSTEM ALARM MODE...

Page 21: ... the cursor to PARITY CHECK then specify a check mode with the or button The default set ting is NONE Available check modes NONE EVEN ODD STOP BIT 1 Move the cursor to STOP BIT then specify a bit length with the or button The default setting is 1 Available bit length 1 2 WAIT TIME The unit will retransmit data when there is no response dur ing the specified wait time 1 Move the cursor to WAIT TIME...

Page 22: ...Select ON or OFF with the or button The default setting is ON Alarm display ALARM on the monitor is enabled or disabled while an alarm is in operation is the alarm channel number ON Enabled OFF Disabled 3 Move the cursor to SITE ALARM Select ON or OFF with the or button The default setting is ON A site alarm motion detection generated by a camera is accepted or ignored ON Enabled OFF Disabled 4 Mo...

Page 23: ...e VS VD con nector when supplied or with the internal sync when VS VD has no input THRU VD2 is supplied when a camera out connector accepts external VD2 from the connected device No VD2 is supplied when no camera out connector accepts external VD2 OFF No VD2 is supplied to the camera 4 Move the cursor to DATA Select ON or OFF with the or button The default setting is ON Data communication with the...

Page 24: ...ction of ALARM REMOTE termi nal on the rear of the unit Input output is specified with internal connection Refer to page 16 for details 1 Move the cursor to TERMINAL Select ALARM or REMOTE with the or button then press SET The default setting is ALARM ALARM Terminals are used as alarm inputs or outputs REMOTE Terminals are used as remote inputs or out puts Setup Menus for Camera Communication Prot...

Page 25: ...retransmit data when there is no response dur ing the specified wait time 1 Move the cursor to WAIT TIME then specify a time with the or button The default setting is OFF Available wait times ms OFF 100 200 400 1 000 8 DELAY TIME This setting specifies a delay time that the unit suspends to return the response to the received command 1 Move the cursor to DELAY TIME then specify a time with the or ...

Page 26: ...ith the activated alarm according to this setup EXT The output is reset when a reset input is supplied to the rear panel or the alarm reset button is pressed on the front panel 1S 5MIN The output is reset when the preset duration elapses OFF No output 6 Move the cursor to ALARM DATA Select an output time with the or button The default setting is AUTO2 The unit notifies the connected System Control...

Page 27: ...OFF No VD2 is supplied to the camera 4 Move the cursor to DATA Select ON or OFF with the or button The default setting is ON Data communication with the selected camera channel is enabled or disabled ON Enabled OFF Disabled 5 Press ESC to return to the SYSTEM menu 8 VS VD input setup This setting specifies the input to the VS VD INPUT terminal on the rear of the unit 1 Move the cursor to VS VD INP...

Page 28: ...Terminal alarm A sensor input is supplied to the unit telling that a change has been detected Site alarm A camera detects motion change in video VMD Video Motion Detection Processing The spot image changes to that of the alarm activated camera when ALARM MODE is set to ON in the setup The camera moves to the preset position ALARM blinks overlaid on the spot image when ALARM DISPLAY is set to ON Th...

Page 29: ...e preset time resets the activated alarm except for the unit s alarm indicator which remains on steady light Alarm Suspension This function is used in the setup operation or whenever you do not wish to accept alarm inputs Press the ALARM SUSPEND button on the front panel or ALM SUSPEND on the controller Alarm inputs will be ignored while the indicator is lit Press the button again to release the a...

Page 30: ...cover Input 1 No Voltage Contact Alarm Reset Output 1 0 5 V O C 16 V 100 mA 4 Spot Switching Input 1 No Voltage Contact Spot Switching Output 1 O C 16 V 100 mA Unit address 1 8 Set with UNIT switch 9 99 Set in Setup menu Operating for System Selection Camera Alarm Data Display Reset Suspend Setup Camera Lens Housing PAN TILT External device control Ambient Operating Temperature 10 C 50 C 14 F 122 ...

Page 31: ... the power switch to set it to the OFF position 2 Press the power switch down to the ON position while pressing the camera selection buttons 2 3 and 4 3 Continue to press the camera selection button approximately 3 seconds after pressing the power switch down to the ON position 4 When all indicators light up resetting is completed 1 Press 2 3 4 ...

Page 32: ...an Gabriel Industrial Park Carolina Puerto Rico 00985 809 750 4300 Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Southern 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Midwest 1707...