PC with WJ-ASC960
Admin Console
System Controller
(Ethernet)
System Controller
(Ethernet)
POWER
ON
OFF
SIGNAL
AUDIO IN
VIDEO OUT
VIDEO IN
100BASE-TX
RS-485
TERM
1
GND
2
3
ON OFF
4
ALARM IN
TRIGGER OUT
RESET
4 3 2 1 G 4 3 2 1 GG V + – G
Encoder 1-1
Encoder 1-2
Decoder 1-1
Decoder 2-1
Switching HUB
Switching HUB
L3SW-1
L2SW
WJ-GXE900
192.168.1.10
POWER
ON
OFF
SIGNAL
AUDIO IN
VIDEO OUT
VIDEO IN
100BASE-TX
RS-485
TERM
1
GND
2
3
ON OFF
4
ALARM IN
TRIGGER OUT
RESET
4 3 2 1 G 4 3 2 1 GG V + – G
WJ-GXE900
192.168.1.11
WJ-GXD900
192.168.2.10
WJ-MPU955A
Equipped with WJ-ASC960
SIGNAL GND
POWER
ON
OFF
3
3
1
4
2
1
4
2
VIDEO OUT
AUDIO OUT
MIX
RESET
1000BASE-T
100BASE-TX
V+ – G
QUAD
PC with WJ-ASC960
Admin Console
Switching
HUB
192.168.1.1
Switching HUB
L3SW-2
WJ-GXD900
192.168.4.10
WJ-MPU955A
Equipped with WJ-ASC960
SIGNAL GND
POWER
ON
OFF
3
3
1
4
2
1
4
2
VIDEO OUT
AUDIO OUT
MIX
RESET
1000BASE-T
100BASE-TX
V+ – G
QUAD
192.168.4.1
192.168.201.1
192.168.201.200
192.168.200.1
192.168.200.200
172.16.192.1
172.18.0.1
172.16.192.2
172.18.0.1
192.168.2.1 192.168.5.1
CPU-1
CPU-2
POWER
ON
OFF
SIGNAL
AUDIO IN
VIDEO OUT
VIDEO IN
100BASE-TX
RS-485
TERM
1
GND
2
3
ON OFF
4
ALARM IN
TRIGGER OUT
RESET
4 3 2 1 G 4 3 2 1 GG V + – G
Encoder 2-1
Encoder 2-2
L2SW
WJ-GXE900
192.168.3.10
POWER
ON
OFF
SIGNAL
AUDIO IN
VIDEO OUT
VIDEO IN
100BASE-TX
RS-485
TERM
1
GND
2
3
ON OFF
4
ALARM IN
TRIGGER OUT
RESET
4 3 2 1 G 4 3 2 1 GG V + – G
WJ-GXE900
192.168.3.11
Switching
HUB
192.168.3.1
192.168.5.2
Cam1-1
Cam1-2
Cam1-4
Cam1-3
Cam1-5
Cam1-6
Cam1-7
Mon1-1
Mon1-2
Mon1-3
Mon1-4
Mon2-1
Mon2-2
Mon2-3
Mon2-4
Domain 1
1
1
8
2
IN
OUT
CASCADE
OUT
16
16
3
15
15
14
14
13
2
1
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
VIDEO
AUDIO IN
AUDIO OUT
MONITOR OUT CASCADE IN
MONITOR (VGA)
ALARM/CONTROL
SERIAL
ALARM
POWER
COPY 1
MODE
EXT STORAGE
10/100BASE-T
RS485(CAMERA)
DATA
AC IN
SIGNAL GND
1
4
2
WJ-HD300A
Series
172.18.0.60
Digital Disk
Recorder 1-1
Digital Disk Recorder 2-1
Cam2-1
Cam2-2
Cam2-4
Cam2-3
Cam2-5
Cam2-6
Cam2-7
Domain 2
1
1
8
2
IN
OUT
CASCADE
OUT
16
16
3
15
15
14
14
13
2
1
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
VIDEO
AUDIO IN
AUDIO OUT
MONITOR OUT CASCADE IN
MONITOR (VGA)
ALARM/CONTROL
SERIAL
ALARM
POWER
COPY 1
MODE
EXT STORAGE
10/100BASE-T
RS485(CAMERA)
DATA
AC IN
SIGNAL GND
1
4
2
WJ-HD300A Series
172.18.0.60
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
15
■
Multiple System Domains with Single GX Switch Node
The following system includes two system domains. Each system domain has its own GX switch node. The system
domain has two WJ-GXE900 encoders and one WJ-GXD900 decoder. It contains a domain WJ-MPU955A CPU with
the WJ-ASC960 upgrade software installed. Within the domain, a PC with WJ-ASC960 Admin Console software
installed is required to configure resources and operations within the domain. The two system domains can work
independently as standalone systems. The sample Local database – 01=multi_1.adm, 02=multi_2.adm -and sys.ini
file – 01A=sys.ini, 02A=sys.ini -for Administration Console are provided on the CD-ROM. The sample Global data-
base - #=multi.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 2.